おすすめの製品
品質水準
メーカー/製品名
Chemicon®
テクニック
cell culture | stem cell: suitable
入力
sample type mesenchymal stem cell(s)
詳細
Excessive weight gain and obesity pose significant health challenges to many industrialized nations. Many metabolic disorders associated with cardiovascular diseases such as diabetes and atherosclerosis are directly linked to the increased production and size of adipose cells. Understanding the molecular mechanism that underlie adipogenesis, the process by which adipose or fat tissue is formed, is thus of critical importance. Elucidation of the steps involved in adipogenesis, including terminal differentiation, have been facilitated in large part by the development of pre-adipocyte cell lines such as the Swiss 3T3-L1 mouse model (Please refer to CHEMICON′s Adipogenesis Assay Kit, Catalog No. ECM950). However using these model systems to study some of the earliest events in cellular differentiation are problematic as these cells are already lineage-restricted and pre-determined to become adipocytes.
Stem cell technology, particularly embryonic stem cells and/or mesenchymal stem cells offer attractive alternative sources of adipocytes for tissue culture studies and for the biochemical dissection of the earliest steps involved in adipose cell determination. Mesenchymal stem cells are multipotent progenitor cells that have the capacity to differentiate into several mesenchymal cell lineages, including bone, cartilage and fat.
Millipore′s Mesenchymal Stem Cell Adipogenesis Kit contains reagents that readily differentiate mesenchymal stem cells to an adipogenic lineage as assessed with Oil Red O staining of lipid vacuoles in mature adipocytes. These factors include dexamethasone, IBMX, insulin and indomethacin. Along with Oil Red O staining solution, a hematoxylin solution is provided to counterstain the cell nucleus.
Using Millipore′s Mesenchymal Stem Cell Adipogenesis Kit, we typically obtain >30% mature adipocytes from the rat bone marrow derived mesenchymal stem cells. Efficiency of adipogenic differentiation may vary, depending upon the quality of the mesenchymal stem cells and if variations to the protocol are introduced.
For Research Use Only; not for use in diagnostic procedure.
アプリケーション
幹細胞研究
構成
IBMX Solution: (Catalog No. 90355) One vial containing 250 μL of 0.5 M 3-isobutyl-1-methylxanthine (IBMX) in DMSO. Store at -20°C.
Insulin Solution: (Catalog No. 90356) Two vials containing 250 μL of 10 mg/mL recombinant human insulin. Store at -20°C.
Indomethacin Solution: (Catalog No. 2003626) Three vials containing 1 mL of 10 mM Indomethacin in methanol. Store at -20°C.
Oil Red O Solution: (Catalog No. 90358) One bottle containing 60 mL 0.36% Oil Red O Solution in 60% isopropanol. Store at room temperature.
Hematoxylin Solution: (Catalog No. 2003732) One bottle containing 50 mL Hematoxylin. Store at room temperature.
保管および安定性
Dexamethasone Solution, IBMX Solution, Insulin Solution and Indomethacin Solution should be stored at -20°C. Oil Red O and Hematoxylin Solutions should be stored at room temperature. Storage of Oil Red O Solution at -20°C may result in formation of insoluble precipitates and is not recommended. If Oil Red O solution forms a precipitate, remove particulates by passage through a 0.22 or 0.45-micron filter.
Precautions:
Oil Red O stains skin and clothing. IBMX, Dexamethasone and Indomethacin are irritants and potentially toxic. DMSO is readily absorbed through the skin. Wear a lab coat and gloves when handling these solutions.
Isopropanol is flammable. Keep solutions containing isopropanol (Oil Red O Solution) away from open flames.
法的情報
免責事項
シグナルワード
Danger
危険有害性の分類
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Eye Irrit. 2 - Flam. Liq. 2 - Repr. 1B - STOT RE 2 Oral - STOT SE 1 - STOT SE 2 - STOT SE 3
ターゲットの組織
Central nervous system, Eyes, Kidney
保管分類コード
3 - Flammable liquids
引火点(°F)
48.2 °F
引火点(℃)
9 °C
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
毒物及び劇物取締法
キットコンポーネントの情報を参照してください
PRTR
キットコンポーネントの情報を参照してください
消防法
キットコンポーネントの情報を参照してください
労働安全衛生法名称等を表示すべき危険物及び有害物
キットコンポーネントの情報を参照してください
労働安全衛生法名称等を通知すべき危険物及び有害物
キットコンポーネントの情報を参照してください
カルタヘナ法
キットコンポーネントの情報を参照してください
Jan Code
キットコンポーネントの情報を参照してください
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
この製品を見ている人はこちらもチェック
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)