MILLIPLEX® Human Kidney Injury Magnetic Bead Panel 1 - Toxicity Multiplex Assay

The analytes available for this multiplex kit are: Calbindin, Collagen IV, Fatty Acid Binding Protein 1 (FABP1), GSTα, IP-10, Kidney Injury Molecule-1 (KIM-1), Renin, TFF-3, TIMP-1.

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
12161503
eCl@ss:
32161000
NACRES:
NA.84

品質水準

化学種の反応性

human

メーカー/製品名

Milliplex®

assay range

accuracy: 73-117%
sensitivity: 0.010-6.473 ng/mL
(MinDC = 2SD)

standard curve range: 0.005-5 ng/mL
(IP-10)

standard curve range: 0.02-25 ng/mL
(Renin)

standard curve range: 0.05-50 ng/mL
(GSTα)

standard curve range: 0.05-50 ng/mL
(KIM-1)

standard curve range: 0.10-100 ng/mL
(TIMP-1)

standard curve range: 0.20-200 ng/mL
(Calbindin)

standard curve range: 0.34-350 ng/mL
(Collagen IV)

standard curve range: 0.49-500 ng/mL
(TFF-3)

standard curve range: 5.86-6,000 ng/mL
(FABP1)

inter-assay cv: <15%
intra-assay cv: <10%

テクニック

multiplexing: suitable

検出方法

fluorometric (Luminex xMAP)

輸送温度

wet ice

詳細

Maintenance of physiological balance in the body is attributed in part to normal kidney function. Altered kidney function due to injury, drug toxicity or kidney failure may be life threatening. Toxicity is the leading cause of drug failure, so research is expanding in search of more sensitive, rapid methods to determine organ-specific damage as quickly as possible. Traditionally, blood urea nitrogen (BUN) and serum creatinine tests have been used to determine drug-induced damage to the kidney. These tests only detect kidney damage after it begins and do not allow for the elucidation of where in the kidney the damage has occurred. Specificity and earlier detection of kidney injury is vital, and this area of research is expanding in search of more sensitive, rapid methods for determining the specific area of damage in kidney.

The MILLIPLEX® portfolio provides valuable research assays to investigate multiple biomarkers of kidney injury in human urine samples using the Luminex® xMAP® instrument platform. The analytes available for this multiplex kit are: Calbindin, Collagen IV, Fatty Acid Binding Protein 1 (FABP1), GSTα, IP-10, Kidney Injury Molecule-1 (KIM-1), Renin, TFF-3, TIMP-1.

Panel Type: Toxicity

特異性

Cross Reactivty
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.

アプリケーション

  • Analytes: Calbindin, Collagen IV, FABP1, GSTα, IP-10, KIM-1, Renin, TFF-3, TIMP-1
  • Recommended Sample type: Urine
  • Recommended Sample dilution: 1:2 in kit Assay Buffer Customers need to determine the optimal dilution factor for their samples. Our recommendations are based on urine samples from normal subjects.
  • Assay Run Time: Overnight
  • Research Category: Toxicity

特徴および利点

Design your multiplex kit by choosing available analytes within this panel.

その他情報

Sensitivity: Please see kit protocol for individual assay sensitivities.

法的情報

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

免責事項

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

ピクトグラム

Skull and crossbonesHealth hazardCorrosionEnvironment

シグナルワード

Danger

危険有害性の分類

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

ターゲットの組織

Respiratory Tract

保管分類コード

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

HKI1MAG-99K-09:
HKI1MAG-99K-11:
HKI1MAG-99K-02:
HKI1MAG-99K:
HKI1MAG-99K-03:
HKI1MAG-99K-04:
HKI1MAG-99K-06:
HKI1MAG-99K-08:
HKI1MAG-99K-01:
HKI1MAG-99K-10:
HKI1MAG-99K-05:
HKI1MAG-99K-07:


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

Irene Capelli et al.
In vivo (Athens, Greece), 34(3), 1333-1339 (2020-05-02)
Acute kidney injury is an important cause of mortality in very-low-birth-weight (VLBW) preterm infants. As in the general population, the detection of renal damage cannot rely on the measurement of serum creatinine, since it has been demonstrated to be a

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)