HANG2MAG-12K

Millipore

MILLIPLEX® Human Angiogenesis Panel 2, HANG2MAG-12K

Angiogenesis Bead-Based Multiplex Assays using the Luminex technology enables the simultaneous analysis of multiple angiogenic biomarkers in human serum, plasma and cell culture samples.

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
12161503
eCl@ss:
32161000
NACRES:
NA.84

品質水準

交差性

human

メーカー/製品名

Milliplex®

assay range

accuracy: 88-97%
standard curve range: 137-100,000 pg/mL
(Thrombospondin-2)

standard curve range: 137-100,000 pg/mL
(sVEGFR2)

standard curve range: 137-100,000 pg/mL
(suPAR)

standard curve range: 14-10,000 pg/mL
(sAXL)

standard curve range: 14-10,000 pg/mL
(sHER3)

standard curve range: 14-10,000 pg/mL
(sVEGFR1)

standard curve range: 27-20,000 pg/mL
(sIL-6Rα)

standard curve range: 27-20,000 pg/mL
(sPECAM-1)

standard curve range: 27-20,000 pg/mL
(sTIE-2)

standard curve range: 274-200,000 pg/mL
(Angiostatin)

standard curve range: 274-200,000 pg/mL
(sE-Selectin)

standard curve range: 274-200,000 pg/mL
(sNeuropilin-1)

standard curve range: 41-30,000 pg/mL
(Osteopontin (OPN))

standard curve range: 41-30,000 pg/mL
(sEGFR)

standard curve range: 41-30,000 pg/mL
(sHER2)

standard curve range: 41-30,000 pg/mL
(sc-Kit/sSCFR)

standard curve range: 412-300,000 pg/mL
(sVEGFR3)

standard curve range: 69-50,000 pg/mL
(sHGFR)

standard curve range: 7-5,000 pg/mL
(PDGF-AB/BB)

テクニック

multiplexing: suitable

検出方法

fluorometric (Luminex xMAP)

輸送温度

wet ice

詳細

Angiogenesis, the development of new vascular networks, is a key process in normal growth and development as well as in wound healing, with homeostasis maintained by a delicate balance of angiogenic factors and inhibitors. Consequently, insufficient, or excessive blood vessel growth underlies many diseases, including cardiovascular disease, diabetic ulcers, macular degeneration, and cancer. Angiogenesis plays a significant role in tumor growth and metastasis.

MILLIPLEX® Human Angiogenesis Magnetic Bead Panel 2 is a 19-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma, cell culture samples, and tissue homogenates/lysates: Angiostatin, soluble E-Selectin, (sE-Selectin), Osteopontin (OPN), Platelet Derived Growth Factor-AB/BB (PDGF-AB/BB), soluble Platelet Endothelial Cell Adhesion Molecule-1 (sPECAM-1), Thrombospondin-2 (TSP-2), soluble AXL (sAXL), soluble c-Kit/Stem Cell Growth Factor Receptor (sc-Kit/SCFR), soluble Epidermal Growth Factor Receptor (sEGFR)†, soluble Human Epidermal Growth Factor Receptor 2 (sHer2), soluble Human Epidermal Growth Factor Receptor 3 (sHer3), soluble Hepatocyte Growth Factor Receptor/c-Met (sHGFR/c-Met), soluble IL-6Rα, soluble Neuropilin-1 (sNRP-1), soluble Tie-2 (sTie-2), soluble Urokinase-type Plasminogen Activator Receptor (suPAR), soluble Vascular Endothelial Growth Factor Receptor 1 (sVEGFR1), soluble Vascular Endothelial Growth Factor Receptor 2 (sVEGFR2), and soluble Vascular Endothelial Growth Factor Receptor 3 (sVEGFR3). This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

†Antibody against active site results in preferential binding to unbound EGFR.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Circulating Cancer

アプリケーション

  • Analytes: Angiostatin, soluble AXL (sAXL) , soluble c-Kit/Stem Cell Growth Factor Receptor (sc-Kit/SCFR), soluble E-Selectin (sE-Selectin), soluble Epidermal Growth Factor Receptor (sEGFR/sErbB1/sHER1)†, soluble Human Epidermal Growth Factor Receptor 2 (sHer2/sHER2/sErbB2), soluble Human Epidermal Growth Factor Receptor 3 (sHer3/ sHER3 / sErbB3), soluble Hepatocyte Growth Factor Receptor (sHGFR/c-Met/sc-Met), soluble IL-6Rα (IL-6Rα (soluble)/sIL-6Rα), soluble Neuropilin-1 (sNRP-1), Osteopontin (OPN), Platelet Derived Growth Factor-AB/BB (PDGF-AB/BB), soluble Platelet Endothelial Cell Adhesion Molecule-1 (sPECAM-1/sCD31), Thrombospondin-2 (TSP-2), soluble Tie-2 (sTie-2), soluble Urokinase-type Plasminogen Activator Receptor (suPAR), soluble Vascular Endothelial Growth Factor Receptor 1 (soluble VEGFR1, sVEGFR1/ sFlt-1), soluble Vascular Endothelial Growth Factor Receptor 2 (soluble VEGFR2/sVEGFR2/ sKDR/sFlk-1), soluble Vascular Endothelial Growth Factor Receptor 3 (soluble VEGFR3/sVEGFR3/ sFlt-4).
  • †Antibody against active site results in preferential binding to unbound EGFR.
  • Recommended Sample Type: Human serum, plasma, cell culture supernatants and tissue/cell homogenates/lysates
  • Recommended Sample Dilution: 25 μL per well of 1:5 diluted plasma or serum; cell culture supernatant may be used undiluted or diluted with appropriate control medium
  • Assay Run Time: Overnight (16-18 hours) at 2-8°C
  • Research Category: Cancer

特徴および利点

Design your multiplex kit by choosing available analytes within this panel.

その他情報

Please contact Technical Service for linearity of dilution.
Sensitivity: See kit protocol for individual analytes sensitivities.

法的情報

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

ピクトグラム

Skull and crossbonesHealth hazardCorrosionEnvironment

シグナルワード

Danger

危険有害性の分類

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

ターゲットの組織

Respiratory Tract

保管分類コード

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

毒物及び劇物取締法

キットコンポーネントの情報を参照してください

PRTR

キットコンポーネントの情報を参照してください

消防法

キットコンポーネントの情報を参照してください

労働安全衛生法名称等を表示すべき危険物及び有害物

キットコンポーネントの情報を参照してください

労働安全衛生法名称等を通知すべき危険物及び有害物

キットコンポーネントの情報を参照してください

カルタヘナ法

キットコンポーネントの情報を参照してください

Jan Code

キットコンポーネントの情報を参照してください


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

Sayuri Padayachee et al.
Nigerian journal of physiological sciences : official publication of the Physiological Society of Nigeria, 37(1), 29-34 (2022-08-11)
A dysregulation of angiogenic mediators has been implicated in HIV infection. Inconsistent data exists on highly active antiretroviral therapy (HAART) usage in pregnancy and its association with PE development. In view of the high prevalence of HIV infection and PE
Juan Pablo Hinestrosa et al.
Communications medicine, 2, 29-29 (2022-05-24)
Detecting cancer at early stages significantly increases patient survival rates. Because lethal solid tumors often produce few symptoms before progressing to advanced, metastatic disease, diagnosis frequently occurs when surgical resection is no longer curative. One promising approach to detect early-stage

関連コンテンツ

The angiogenesis pathway is complex with many targets to analyze. Simultaneous quantification of multiple markers, with the MILLIPLEX® Human Angiogenesis/Growth Factor Panel 1, saves valuable resources. See how this panel was used to correlate angiogenesis biomarkers with early metastatic progression in NSCLC.

Detection of cancer biomarkers through multiplex cancer assays can accelerate studies of normal homeostasis and tumorigenic processes. See how MILLIPLEX® multiplex cancer assays are advancing various cancer research areas including lung cancer, breast cancer, and immuno-oncology research.

化粧品やパーソナルケア製品の研究において、イムノアッセイを使用して炎症や感作、老化、組織再生に関するバイオマーカーを評価し、化粧品の潜在的な有害作用を調べる方法についてご紹介します。

Learn how immunoassays are used in cosmetics and personal care research to discover potential harmful effects of cosmetics products, and assess markers of inflammation, sensitization, aging, and tissue regeneration among others.

すべて表示

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)