コンテンツへスキップ
Merck

03-0190-00

Millipore

SMC® Human IL-18 High Sensitivity Immunoassay Kit

別名:

IGIF immunoassay kit, IL-18 Single Molecule Counting Kit, IL-18 ultra-sensitive immunoassay, Interleukin-18 immunoassay kit

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
12161503
NACRES:
NA.84

化学種の反応性

mouse, feline, rat

メーカー/製品名

SMC®

assay range

sensitivity: 0.09 pg/mL
(Lower Limit of Quantification)

inter-assay cv: 7%
intra-assay cv: 4%
(five normal plasma samples run in triplicate by 3 different operators on 3 different days.)

テクニック

single molecule counting: suitable

保管温度

2-8°C

詳細

The SMC® Human IL-18 High Sensitivity Immunoassay Kit contains all reagents required to perform the assay. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format.
Assay protocols are similar to existing sandwich ELISA methods with two key differences:
1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification.
2) The Erenna and SMCxPRO® immunoassay systems detect analytes using Single Molecule Counting (SMC®) technology.

特異性

Species Reactivity:
Specificity to the following species recombinant proteins were tested with the following results:
Feline – 0.5% Mouse – 4% Rat – 0.3%

Cross Reactivity:
No cross-reactivity was seen with the following cytokines: IL-1a, IL-1ß, IL-1RA, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-10, IL-12 (p40), IL-12 (p70), IL-13, IL-15, IL-17A, IL-17E, IL-7F, IL-22, IL-27.

Accuracy:
  • Minimum of 5 serum samples spiked with average recovery of 99% with a range of 92-107%
  • Minimum of 5 plasma samples spiked with average recovery of 95% with a range of 88-103%

アプリケーション

The sensitivity of the Single Molecule Counting (SMC®) technology gives the SMC® Human IL-18 High Sensitivity Immunoassay Kit unparalleled performance in the quantification of IL-18 in human serum and plasma.

This new streamline kit has the following features including:
  • Improved options for sample prep and incubation
  • Lyophilization of the standard provides the kit at one storage condition
  • Increased reagent volumes to accommodate automation
  • Validated to run on both SMCxPRO® and Erenna


Research Category:
Inflammation & Immunology

Research Sub-Category:
  • Inflammatory Disease,
  • Immune Response
  • Autoimmune disease

包装

96 well assay

構成

  • Assay Buffer
  • IL-18 Coated Beads
  • Standard Diluent
  • IL-18 Detection Antibody
  • IL-18 Standard
  • 10X Wash Buffer
  • Buffer D
  • Elution Buffer B

法的情報

SMC is a registered trademark of Singulex
SMCxPRO is a registered trademark of Merck KGaA, Darmstadt, Germany

免責事項

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

ピクトグラム

Skull and crossbonesHealth hazard

シグナルワード

Danger

危険有害性の分類

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B

保管分類コード

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

03-0190-00:


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

関連コンテンツ

1分子カウント(Single Molecule Counting、SMC™)技術を用いた高感度イムノアッセイにより、免疫学研究を推進し、インターフェロン、インターロイキン、免疫グロブリンを正確に特性評価する方法を説明します。

See how you can enhance your immunology research through the power of high sensitivity immunoassays by harnessing Single Molecule Counting (SMC®) technology to precisely characterize interferons, interleukins, and immunoglobins.

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)