Passa al contenuto
Merck
  • Embedment of Ag(I)-organic frameworks into silica gels for microextraction of polybrominated diphenyl ethers in soils.

Embedment of Ag(I)-organic frameworks into silica gels for microextraction of polybrominated diphenyl ethers in soils.

Journal of chromatography. A (2015-01-27)
Chao-Yan Zhang, Zeng-Guang Yan, You-Ya Zhou, Lin Wang, Ya-Bo Xie, Li-Ping Bai, Hui-Yan Zhou, Fa-Sheng Li
ABSTRACT

Three Ag(I)-organic frameworks, [Ag5(pydc)2(CN)]n, {[Ag4(pydc)2]CH3CN}n, and [Ag(4,4'-bpy)NO3]n, were synthesized and embedded into silica gels to form metal-organic-framework (MOF)-embedded gels for the microextraction of polybrominated diphenyl ethers (PBDEs) in soils. Despite the great differences in the structures of the organic ligands, all three Ag(I)-organic frameworks were found to effectively accumulate and concentrate PBDEs from sample solutions prepared with contaminated soil and purified water, indicating the important roles of Ag centers in PBDE extraction. Under the optimal experimental conditions (MOF mass, water volume, temperature, extraction time, and back-extraction time) for PBDE extraction from sample solutions, the detection limits of seven PBDEs (BDE-28, 47, 99, 100, 153, 154, and 183) ranged from 0.01 to 2.6ngg(-1) for [Ag5(pydc)2(CN)]n, 0.20-0.64ngg(-1) for {[Ag4(pydc)2]CH3CN}n, and 0.60-3.08ngg(-1) for [Ag(4,4'-bpy)NO3]n. The reproducibilities of the three methods were all satisfactory with relative standard deviations (RSDs) in the range of 2.2-9.6%, 5.3-10.4%, and 6.9-9.4% for [Ag5(pydc)2(CN)]n, {[Ag4(pydc)2]CH3CN}n, and [Ag(4,4'-bpy)NO3]n, respectively. The use of Ag(I)-organic frameworks for the microextraction of PBDEs was validated using both certified reference soils and field-contaminated soils, and the proposed methods are recommended as rapid and environmentally friendly alternatives for the extraction and determination of PBDEs in soils.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Acido trifluoroacetico, ReagentPlus®, 99%
Sigma-Aldrich
Acido trifluoroacetico, suitable for HPLC, ≥99.0%
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%
Sigma-Aldrich
Toluene, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Acido trifluoroacetico, puriss. p.a., suitable for HPLC, ≥99.0% (GC)
Sigma-Aldrich
tetra-etil ortosilicato, reagent grade, 98%
Sigma-Aldrich
2,2,4-trimetilpentano, ACS reagent, ≥99.0%
Sigma-Aldrich
tetra-etil ortosilicato, ≥99.0% (GC)
Sigma-Aldrich
Acido trifluoroacetico, ≥99%, for protein sequencing
Sigma-Aldrich
2,2,4-trimetilpentano, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.5%
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%
Sigma-Aldrich
tetra-etil ortosilicato, 99.999% trace metals basis
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Sigma-Aldrich
4,4′−Dipyridyl, 98%
Supelco
Toluene, analytical standard
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Sigma-Aldrich
2,2,4-trimetilpentano, anhydrous, 99.8%
Sigma-Aldrich
Poly(dimethylsiloxane), viscosity 1.0 cSt (25 °C)