2,3,4,6-Tetra-O-acetyl-β-D-glucopyranosyl isothiocyanate

for chiral derivatization, LiChropur, ≥98.0% (HPLC)

Sinonimo/i:

GITC

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula empirica (notazione di Hill):
C15H19NO9S
Numero CAS:
Peso molecolare:
389.38
Beilstein:
56699
Numero MDL:
Codice UNSPSC:
12000000
ID PubChem:
NACRES:
NA.22

Grado

for chiral derivatization

Saggio

≥98.0% (HPLC)

Qualità

LiChropur

tecniche

HPLC: suitable

Punto di fusione

114-116 °C (lit.)

Temperatura di conservazione

2-8°C

Stringa SMILE

CC(=O)OC[C@H]1O[C@@H](N=C=S)[C@H](OC(C)=O)[C@@H](OC(C)=O)[C@@H]1OC(C)=O

InChI

1S/C15H19NO9S/c1-7(17)21-5-11-12(22-8(2)18)13(23-9(3)19)14(24-10(4)20)15(25-11)16-6-26/h11-15H,5H2,1-4H3/t11-,12-,13+,14-,15-/m1/s1
WOWNQYXIQWQJRJ-UXXRCYHCSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

2,3,4,6-Tetra-O-acetyl-β-D-glucopyranosyl isothiocyanate is a chiral derivatization reagent which reacts mainly with enantiomeric amino acids.

Applicazioni

Chiral reagent for resolution of amino acid derivatives.
GITC may have been used in the formation of diastereomers and for reversed-phase high-performance liquid chromatographic resolution of amino acid enantiomers.

Confezionamento

Bottomless glass bottle. Contents are inside inserted fused cone.

Prodotti consigliati

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

Note legali

LiChropur is a trademark of Merck KGaA, Darmstadt, Germany

Pittogrammi

Health hazardExclamation mark

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Eye Irrit. 2 - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

Organi bersaglio

Respiratory system

Codice della classe di stoccaggio

11 - Combustible Solids

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable

Dispositivi di protezione individuale

dust mask type N95 (US), Eyeshields, Faceshields, Gloves


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 1

1 of 1

Zhiqiong Chen et al.
Journal of separation science, 28(2), 193-196 (2005-03-10)
Chiral separation of racemic mixtures is of the greatest importance to the pharmaceutical industry, as the isomers of a given racemate may exhibit substantially different pharmacological effects, not to mention possibly differing toxicity behaviour. A novel chiral separation method is
J Gal et al.
Journal of pharmacological methods, 16(3), 261-269 (1986-11-01)
Many established and experimental adrenergic agonists are derivatives of 2-aminoethanol with a phenol or catechol moiety in the 1-position. There is considerable interest in the stereochemical aspects of the actions of such chiral drugs. Surprisingly, however, little has been published
X Li et al.
Journal of chromatography. B, Biomedical sciences and applications, 742(2), 433-439 (2000-07-20)
A reversed-phase high-performance liquid chromatographic method for the determination of the enantiomers of atenolol in rat hepatic microsome has been developed. Racemic atenolol was extracted from alkalinized rat hepatic microsome by ethyl acetate. The organic layer was dried with anhydrous
Sherry Wang et al.
Journal of pharmaceutical and biomedical analysis, 43(2), 701-707 (2006-09-09)
A stable isotopically labeled (SIL) analogue is believed to be the most appropriate internal standard in a quantitative bioanalytical liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay. It is assumed that a SIL internal standard always compensates for variability in chemical derivatization
Klaas E A Max et al.
Proceedings of the National Academy of Sciences of the United States of America, 115(23), E5334-E5343 (2018-05-20)
Circulating extracellular RNAs (exRNAs) have the potential to serve as biomarkers for a wide range of medical conditions. However, limitations in existing exRNA isolation methods and a lack of knowledge on parameters affecting exRNA variability in human samples may hinder

Protocolli

Enantiomeric analysis of neurotransmitters and pharmaceuticals carrying functional amino groups, ß-adrenergic blockers; penicillamine, mexiletine; fine chemicals such as 1-phenyl-2-aminoethanol.

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.