Passa al contenuto
Merck
Tutte le immagini(3)

Documenti

MSHMAG-21K

Millipore

MILLIPLEX® Multi-Species Hormone Magnetic Bead Panel

The Multi-Species Hormone Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 5 steroid/thyroid biomarkers in human serum, plasma and cell culture samples.

Sinonimo/i:

luminex multiple species thyroid reproductive stress endocrine metabolic hormones multiplex assay, millipore multiple species metabolism hormones multiplex kit, multi species hormone immunoassay panel

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
12161503
eCl@ss:
32161000
NACRES:
NA.47

Livello qualitativo

Reattività contro le specie

human, canine

Produttore/marchio commerciale

Milliplex®

assay range

accuracy: 105%
(Canine Samples: T3)

accuracy: 80%
(Canine Samples: Estradiol)

accuracy: 85%
(Human Samples: Progesterone)

accuracy: 87%
(Canine Samples: T4)

sensitivity: 0.01 ng/mL
(MinDC+2SD; Estradiol)

sensitivity: 0.12 ng/mL
(MinDC+2SD; T3)

sensitivity: 0.25 ng/mL
(MinDC+2SD; Progesterone)

sensitivity: 0.33 ng/mL
(MinDC+2SD; Cortisol)

sensitivity: 0.51 ng/mL
(MinDC+2SD; T4)

standard curve range: 0.014-10 ng/mL
(Estradiol)

standard curve range: 0.07-50 ng/mL
(T3)

standard curve range: 0.14-100 ng/mL
(Progesterone)

standard curve range: 0.27-200 ng/mL
(Cortisol)

standard curve range: 0.34-250 ng/mL
(T4)

inter-assay cv: <10%
intra-assay cv: <10%
(Cortisol)

inter-assay cv: <15%
intra-assay cv: <10%
(Estradiol)

inter-assay cv: <15%
intra-assay cv: <10%
(Progesterone)

inter-assay cv: <15%
intra-assay cv: <10%
(T3)

inter-assay cv: <15%
intra-assay cv: <10%
(T4)

tecniche

multiplexing: suitable

Metodo di rivelazione

fluorometric (Luminex xMAP)

Condizioni di spedizione

ambient

Descrizione generale

Steroid and thyroid hormones are small molecule endocrine hormones secreted from adrenal glands (cortisol), ovaries (estradiol and progesterone), and the thyroid (T3 and T4). These hormones play key roles in the regulation of energy balance, mental and physical development, sex organ development, reproduction, and pregnancy. These hormones play a role in the patho-physiology of many diseases such as thyroid-related diseases (Grave’s disease and hyper/hypothyroidism), steroid-related diseases (Cushing’s syndrome) and stress related diseases. Endocrine disrupting chemincals (EDC) can impact normal functioning of steroid and thyroid hormones.

The MILLIPLEX® Multi-Species Hormone Panel is a 5-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and cell/tissue culture samples: Cortisol, Estradiol, Progesterone, T3 and T4. This multi-species kit may be used to detect these analytes in human, dog, rat, mouse, cynomolgous monkey, rhesus monkey, horse, rabbit, cat, guinea pig, pig and hamster. The kit has been verified with human and canine samples. The amount of cross-reactivity to other species has been confirmed, but not tested to the same level of verification as was used for human and canine. All analytes in this kit are run in a competitive assay format. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Endocrine

Specificità

Approximately 10% cross-reactivity to Cortisol is observed in the Progesterone assay and approximately 5% cross-reactivity to T3 is observed in the T4 assay. No other significant cross-reactivity is observed within the panel or to other similar analytes.

This multi-species kit may be used to detect these 5 analytes in human, dog, rat, mouse, cynomolgous monkey, rhesus monkey, horse, rabbit, cat, guinea pig, pig and hamster. However, the kit was fully validated with human and canine samples only and the amount of cross-reactivity to other species tested has not been determined.
Cross Reactivty
Approximately 10% cross-reactivity to Cortisol is observed in the Progesterone assay and approximately 5% cross-reactivity to T3 is observed in the T4 assay. No other significant cross-reactivity is observed within the panel or to other similar analytes.

Applicazioni

  • Analytes: Cortisol, Estradiol, Progesterone, T3, T4
  • NOTE: This multi-species kit may be used to detect these analytes in human, dog, rat, mouse, cynomolgus monkey, rhesus monkey, horse, rabbit, cat, guinea pig, pig and hamster. However, the kit was validated with human and canine samples only and the amount of cross-reactivity to other species tested, has not been determined.
  • NOTE: This assay requires an extraction step for serum and plasma samples (instructions are provided in the kit protocol).
  • NOTE: This is a competitive immunoassay
  • Recommended Sample Type: Serum, plasma, or tissue/cell culture supernatants or lysates from multiple species
  • Recommended Sample Dilution: 25 μL per well of undiluted extracted serum or plasma. Tissue/cell culture samples may be run neat or diluted in an appropriate control media.
  • Assay Run Time: Overnight (16-20 hours) at 2-8°C.
  • Research Category: Metabolism
  • Research Category: Endocrine

Caratteristiche e vantaggi

Design your multiplex kit by choosing available analytes within this panel.

Confezionamento

96 well plate
Everything you need in a single kit.

Linkage

Replaces: STTHMAG-21K

Stoccaggio e stabilità

Recommended storage for kit components is 2 - 8°C.

Altre note

Please contact Technical Service for linearity of dilution.

Note legali

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Esclusione di responsabilità

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Avvertenze

Danger

Classi di pericolo

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

Organi bersaglio

Respiratory Tract

Codice della classe di stoccaggio

10 - Combustible liquids


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Gabriela Leite et al.
Menopause (New York, N.Y.), 29(3), 264-275 (2022-02-26)
Hormone therapy (HT) is used to treat menopause-related conditions and symptoms. The small intestine plays key roles in metabolic and endocrine function, but the effects of HT on the small intestinal microbiome are unknown. Here, we characterize duodenal microbiome differences
Christian K Garcia et al.
PloS one, 17(10), e0275715-e0275715 (2022-10-14)
The capability of male mice to exercise in hot environments without succumbing to exertional heat stroke (EHS) is markedly blunted compared to females. Epidemiological evidence in humans and other mammals also suggests some degree of greater vulnerability to heat stroke

Contenuto correlato

The newer xMAP® Sheath Fluid PLUS formulation contains 3 modes of microbial action to eliminate potential environmental microbial resistance. See how the preparations compare in this performance comparison of the previous xMAP® Sheath Fluid to the new xMAP® Sheath Fluid PLUS formulation in MILLIPLEX® multiplex assays.

Learn the benefits of using biomarker detection multiplex immunoassays for laboratory, companion, and agricultural animal research and explore MILLIPLEX® multiplex assays for veterinary medicine and animal health research.

Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.