Passa al contenuto
Merck
Tutte le immagini(2)

Documenti fondamentali

HPTP1MAG-66K

Millipore

MILLIPLEX® Human Pituitary Magnetic Bead Panel 1 - Endocrine Multiplex Assay

The Human Pituitary Panel 1, using the Luminex xMAP technology, enables the simultaneous analysis of 7 protein biomarkers in human serum, plasma and cell culture samples.

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
12161503
eCl@ss:
32161000
NACRES:
NA.47

Livello qualitativo

Reattività contro le specie

human

Produttore/marchio commerciale

Milliplex®

assay range

accuracy: 105%
(TSH)

accuracy: 77%
(AGRP)

accuracy: 87%
(LH)

accuracy: 97%
(FSH)

sensitivity: 0.02 μIU/mL
(minDC+2SD; TSH)

sensitivity: 0.02 mIU/mL
(minDC+2SD; FSH)

sensitivity: 0.02 mIU/mL
(minDC+2SD; LH)

sensitivity: 1.12 pg/mL
(minDC+2SD; AGRP)

sensitivity: 2.4 pg/mL
(minDC+2SD; ACTH)

sensitivity: 6.88 pg/mL
(minDC+2SD; GH)

sensitivity: 84.42 pg/mL
(minDC+2SD; CNTF)

standard curve range: 0.024-100 mIU/mL
(FSH)

standard curve range: 0.039-160 μIU/mL
(TSH)

standard curve range: 0.049-200 mIU/mL
(LH)

standard curve range: 122-500,000 pg/mL
(CNTF)

standard curve range: 2.4-10,000 pg/mL
(AGRP)

standard curve range: 2.4-10,000 pg/mL
(GH)

standard curve range: 3.0-12,500 pg/mL
(ACTH)

inter-assay cv: <15%
intra-assay cv: <10%
(ACTH)

inter-assay cv: <15%
intra-assay cv: <10%
(AgRP)

inter-assay cv: <15%
intra-assay cv: <10%
(CNTF)

inter-assay cv: <15%
intra-assay cv: <10%
(FSH)

inter-assay cv: <15%
intra-assay cv: <10%
(GH)

inter-assay cv: <15%
intra-assay cv: <10%
(LH)

inter-assay cv: <15%
intra-assay cv: <10%
(TSH)

tecniche

multiplexing: suitable

Metodo di rivelazione

fluorometric (Luminex xMAP)

Condizioni di spedizione

wet ice

Descrizione generale

Called the “master gland” because it controls many other endocrine glands, the pituitary secretes several key hormones that play important roles in the regulation of metabolism, growth, and reproduction. Piuitary hormones are responsible for the stimulation of the adrenal gland (ACTH), thyroid gland (TSH), ovaries and testes (FSH, LH), as well as blood pressure and the amount of water excreted by the kidneys. Through its connection with the pituitary, the hypothalamus modulates endocrine function by detecting hormone levels.

The MILLIPLEX® Human Pituitary Panel 1 is a 7-plex kit to be used for the simultaneous measurement of any or all of the following analytes in human serum, plasma or cell/tissue culture samples: ACTH, AGRP, CNTF, FSH, GH, LH, and TSH. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Endocrine

Specificità

Cross Reactivty
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.

Applicazioni

  • Analytes: ACTH, Agouti-Related Protein (AGRP), CNTF, FSH, GH, LH, TSH
  • Recommended Sample Type: Human serum, plasma, cerebrospinal fluid (CSF), tissue/cell lysates and supernatants Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma. Cell/tissue culture samples may be run neat or appropriately diluted in control media
  • Assay Run Time: Overnight (16-18 hr) at 2-8°C
  • Research Category: Endocrine
  • Research Subcategory: Metabolism

Caratteristiche e vantaggi

Design your multiplex kit by choosing available analytes within this panel.

Confezionamento

96 well plate
Everything you need in a single kit.

Stoccaggio e stabilità

Recommended storage for kit components is 2 - 8°C.

Altre note

Please contact Technical Service for linearity of dilution.

Note legali

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Esclusione di responsabilità

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pittogrammi

Skull and crossbonesEnvironment

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1

Codice della classe di stoccaggio

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Contenuto correlato

Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.