1.51022
TLC aluminum sheets, silica gel 60 F254 MS-grade
pkg of 20 sheets, sheet L × W 5 cm × 7.5 cm, aluminum support
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Materiali
aluminum support
silica gel 60 matrix
Livello qualitativo
Caratteristiche
binder Organic Polymer
fluorescent indicator
Confezionamento
pkg of 20 sheets
tecniche
TLC-MS: suitable
thin layer chromatography (TLC): suitable
Spessore strato
100 μm
Lungh. × largh. foglio
5 cm × 7.5 cm
Dimensione particelle
10-12 μm
Dimensione pori
60 Å medium pore diameter
Temperatura di conservazione
2-30°C
Descrizione generale
20 Aluminium sheets 5x7.5
Reference:
Gertrud Morlock, Wolfgang Schwack
Coupling of planar chromatography to mass spectrometry
TrAC Trends in Analytical Chemistry, Volume 29, Issue 10, 2010, Pages 1157-1171
Gertrud Morlock, Wolfgang Schwack
Coupling of planar chromatography to mass spectrometry
TrAC Trends in Analytical Chemistry, Volume 29, Issue 10, 2010, Pages 1157-1171
Risultati analitici
Specific surface area (according toBET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume(N₂-isotherm):0.74 - 0.84 ml/g
d 50 (laserdiffraction, size distribution): 9.7 - 11.7 µm
Layerthickness: 80 - 120 µm
Deviationof layer thickness per plate: ≤ 30 µm
A) colour test
hRf-values
- bleu viforganol, lipophile: 15 - 25
- CeresBlack G, lipophile: 38 - 49
- ceresViolet brn, lipophile: 53 – 65
Typical value determined on a conditioned sheet
Eluent: Toluene (45% rel. humidity)
B) MS suitability test
- Angiotensin II (signal-to-noiseratio 50ng): ≥ 25
measured with 5000 shots
- Caffeine (signal-to-ratio 5ng): ≥25
Pore volume(N₂-isotherm):0.74 - 0.84 ml/g
d 50 (laserdiffraction, size distribution): 9.7 - 11.7 µm
Layerthickness: 80 - 120 µm
Deviationof layer thickness per plate: ≤ 30 µm
A) colour test
hRf-values
- bleu viforganol, lipophile: 15 - 25
- CeresBlack G, lipophile: 38 - 49
- ceresViolet brn, lipophile: 53 – 65
Typical value determined on a conditioned sheet
Eluent: Toluene (45% rel. humidity)
B) MS suitability test
- Angiotensin II (signal-to-noiseratio 50ng): ≥ 25
measured with 5000 shots
- Caffeine (signal-to-ratio 5ng): ≥25
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
I clienti hanno visto anche
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.