WHA13549204
Whatman® FF170HP Din A
sheets nitrocellulose membrane, pack of 10 sheets
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Materiali
polyester backing
sheets nitrocellulose membrane
Sterilità
non-sterile
Confezionamento
pack of 10 sheets
Produttore/marchio commerciale
Whatman 13549204
Misura
210 m × 297 mm
Spessore
200 μm
Descrizione generale
FF High Performance (HP) membranes are part of the AE family, which are directly cast onto a plastic film. The FFHP membranes are a result of improved membrane casting procedures, which result in enhanced intra- and inter lot consistency and sharper lines. The surface is uniform without unincorporated nitrocellulose powder and the fine structure fiber distribution provides large internal surfaces for binding proteins
Nitrocellulose membranes are a key functional part of lateral-flow assays. The membrane must provide sufficient protein binding to enable the formation of a sharp and intense capture line, but at the same time the level of nonspecific background must be low for easy interpretation of results. Nitrocellulose membranes are available in a range of wicking rates and formulations. It has long been known that the wicking rate of a membrane has a significant impact on test sensitivity.
Nitrocellulose membranes are a key functional part of lateral-flow assays. The membrane must provide sufficient protein binding to enable the formation of a sharp and intense capture line, but at the same time the level of nonspecific background must be low for easy interpretation of results. Nitrocellulose membranes are available in a range of wicking rates and formulations. It has long been known that the wicking rate of a membrane has a significant impact on test sensitivity.
Caratteristiche e vantaggi
A backed and highly consistent membrane for use with low viscosity samples in a lateral flow assay.
- Exceptional intra- and inter-lot consistency as demonstrated by a coefficient of variation (CV) for capillary rise of < 10%.</LI>Improved assay consistency and reproducible limit of detection.
- Reduced assay optimization costs, compared to a less consistent membrane.
Note legali
Whatman is a registered trademark of Cytiva
Avvertenze
Warning
Indicazioni di pericolo
Consigli di prudenza
Codice della classe di stoccaggio
11 - Combustible Solids
Scegli una delle versioni più recenti:
Certificati d'analisi (COA)
Ci dispiace, ma al momento non ci sono COA disponibili online per questo prodotto.
Se ti serve aiuto, non esitare a contattarci Servizio Clienti
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
I clienti hanno visto anche
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.