跳转至内容
Merck
所有图片(1)

主要文件

SU860097

Supelco

顶空瓶,螺旋盖,圆底(仅小瓶),100个装

volume 20 mL, clear glass vial, thread for 18, O.D. × H 22.5 mm × 75.5 mm, pkg of 100 ea

别名:

Screw cap rounded bottom headspace vial

登录查看公司和协议定价


About This Item

分類程式碼代碼:
41122001
NACRES:
NB.11

材料

clear glass vial
round bottom

特點

closure type screw top vial

包裝

pkg of 100 ea

外徑 × 高度

22.5 mm × 75.5 mm

容積

20 mL

接頭

thread for 18

相容性

for use with CTC PAL (Varian, Gerstel, Atas, Shimadzu)

正在寻找类似产品? 访问 产品对比指南

一般說明

这些样品瓶需要带 18mm 螺纹的专用瓶盖。标准 18-400 螺纹瓶盖不适合该样品瓶。这些样品瓶可用的瓶盖货号为 SU860101(PTFE/硅树脂,1.3mm 厚)、SU860102(PTFE/丁基橡胶,1.6mm 厚)和 SU860103(PTFE/硅树脂,1.5mm 厚)。这些瓶盖使用不锈钢材料并具有磁性。

應用

顶空瓶可用于以下用途:
  • 通过自动平衡顶空气相色谱法和气相校准 (VPC),在独立分析小瓶中存在的乙酸乙酯总量的情况下,测定 0°C水中乙酸乙酯的分配系数。
  • 在通过 GC-MS 开发和优化顶空 SPME 方法期间,它可用于分析药品中存在的挥发性极性残留溶剂。
  • 它还可用于 C 3 和 C 4 牧草叶水的 18 O 同位素分析,在建立叶脉中的草地特征时,发现具有不同光合途径的牧草具有不同的叶脉间差异。
  • 它也可以应用于荧光假单胞菌挥发性卤代脂肪烃,如 1,2-二氯乙烷和 1,2-二氯丙烷的代谢研究,这些都是地下蓄水层的主要污染物。

从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

抱歉,我们目前尚未线上提供该产品的COA。

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Determination of partition coefficients by automatic equilibrium headspace gas chromatography by vapor phase calibration.
Welter KBC and Bichler C.
Chromatographia, 34 (5-8), 235-240 (1992)
B R Helliker et al.
Proceedings of the National Academy of Sciences of the United States of America, 97(14), 7894-7898 (2000-07-08)
We show that 18O evaporative enrichment of bulk leaf water in grass species can be significantly more enriched than predicted by the Craig-Gordon model, with C4 grasses considerably more enriched than C3 grasses. Our results suggest that the unanticipated 18O
P A Vandenbergh et al.
Applied and environmental microbiology, 54(10), 2578-2579 (1988-10-01)
A Pseudomonas fluorescens strain designated PFL12 was isolated from soil and water that were contaminated with various chloroaliphatic hydrocarbons. The isolate was able to metabolize 1,2-dichloroethane, 1,1,2-trichloroethane, 1,2-dichloropropane, 2,2-dichloropropane, and trichloroethylene.
C C Camarasu
Journal of pharmaceutical and biomedical analysis, 23(1), 197-210 (2000-07-18)
A solid-phase microextraction (SPME) method has been developed and optimized for the polar residual solvent determination in pharmaceutical products. Five different polymer-coated fibers were investigated and the Carboxen/polydimethylsiloxane was found to be the most sensitive for all components. Two Headspace

实验方案

High performance, reliability, and reproducibility of HS-SPME in combination with GC/MS for the determination of VOCs in water was proven in an interlaboratory trial. The new ISO 17943 using HS-SPME is an improvement on existing official methods for this determination in terms of sensitivity and selectivity.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门