推荐产品
ligand
butyl
包裝
pkg of 4.7 mL
製造商/商標名
Cytiva 28-9269-84
參數
1.5 bar (22 psi) (Over the Packed Bed During Operation)
22 psi
床尺寸
7.7 mm × 100 mm
床體積
4.7 mL
柱內徑
7.7 mm
基質
4% cross-linked agarose
粒徑
45-165 μm
平均直徑
90 μm
cleaning
2-14
工作範圍
3-13
適合性
suitable for bioprocess medium
一般說明
HiScreen Butyl FF columns are prepacked with Butyl Sepharose 4 Fast Flow hydrophobic interaction chromatography (HIC) resins. The columns are an excellent choice for method optimization and parameter screening.
The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.
If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.
Media prepacked in HiScreen HIC columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.
The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.
If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.
Media prepacked in HiScreen HIC columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.
特點和優勢
- Butyl Sepharose 4 Fast Flow is a well-established, standard aliphatic HIC medium for capture and intermediate purification.
- Prepacked, ready-to-use columns for convenient process development optimization.
- 1NA cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
- Easily connected in series to achieve 2NA cm bed height.
- Small bed volume gives fast results and minimal sample/buffer consumption.
- Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity.
儲存和穩定性
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol or 0.01 M NaOH)
Store at 4 to 30 °C (20% Ethanol)
分析報告
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
法律資訊
HiScreen is a trademark of Cytiva
訊號詞
Warning
危險聲明
儲存類別代碼
3 - Flammable liquids
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门