推荐产品
產品線
BioXtra
化驗
≥99.0% (titration)
形狀
crystalline
雜質
≤0.0005% Phosphorus (P)
≤0.1% Insoluble matter
燃燒殘留物
≤0.2%
pH值
2.5-5.0 (25 °C, 213.3 g/L)
有用的pH值範圍
6.4-7.8
pKa (25 °C)
7.1
溶解度
H2O: 1 M, clear, colorless
負離子痕跡
chloride (Cl-): ≤0.05%
sulfate (SO42-): ≤0.05%
正離子痕跡
Al: ≤0.0005%
Ca: ≤0.0005%
Cu: ≤0.0005%
Fe: ≤0.0005%
K: ≤0.005%
Mg: ≤0.0005%
NH4+: ≤0.05%
Na: ≤0.005%
Pb: ≤0.001%
Zn: ≤0.0005%
吸收
≤0.080 at 280 in H2O at 1 M
≤0.095 at 260 in H2O at 1 M
SMILES 字串
OCCN(CCO)CCS(O)(=O)=O
InChI
1S/C6H15NO5S/c8-4-1-7(2-5-9)3-6-13(10,11)12/h8-9H,1-6H2,(H,10,11,12)
InChI 密鑰
AJTVSSFTXWNIRG-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
dust mask type N95 (US), Eyeshields, Gloves
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 10(12), 1449-1455 (2014-11-26)
Stent fracture is important because it may cause adverse events. The interventional cardiologist needs independent data to aid stent selection. Stent designers need data to improve stent design. We used a repetitive bend test to compare durability and fracture for
Circulation journal : official journal of the Japanese Circulation Society, 79(6), 1323-1331 (2015-04-07)
Coronary adventitia harbors a wide variety of components, such as inflammatory cells and vasa vasorum (VV). Adventitial VV initiates the development of coronary artery diseases as an outside-in supply route of inflammation. We have recently demonstrated that drug-eluting stent implantation
The journal of physical chemistry letters, 6(15), 2933-2937 (2015-08-13)
Colloidal CdSe quantum dot (QD) core ensembles were photodimmed and allowed to recover in the dark using ambient thermal energy at a range of temperatures. Nonlinear thermal recovery is well described by a stretched exponential function, and further analysis yields
Nano letters, 15(7), 4657-4663 (2015-06-24)
Noncrystalline semiconductor materials often exhibit hysteresis in charge transport measurements whose mechanism is largely unknown. Here we study the dynamics of charge injection and transport in PbS quantum dot (QD) monolayers in a field effect transistor (FET). Using Kelvin probe
International journal of cardiology, 186, 178-185 (2015-04-02)
Numerous studies have demonstrated an association between endothelial shear stress (ESS) and neointimal formation after stent implantation. However, the role of ESS on the composition of neointima and underlying plaque remains unclear. Patients recruited in the Comfortable AMI-IBIS 4 study
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门