About This Item

线性分子式:
C6H4(CH3)2
CAS号:
分子量:
106.17
Beilstein:
1815558
EC號碼:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

certified reference material
pharmaceutical secondary standard

品質等級

agency

traceable to NIST 3003
traceable to USP 1601849

蒸汽密度

3.7 (vs air)

蒸汽壓力

<0.1 atm ( 21.1 °C)
16 mmHg ( 37.7 °C)
7 mmHg ( 20 °C)

CofA

current certificate can be downloaded

自燃溫度

867 °F

expl. lim.

7 %

技術

HPLC: suitable
gas chromatography (GC): suitable

折射率

n20/D 1.505 (lit.)

bp

143-145 °C (lit.)

mp

-26--23 °C (lit.)

密度

0.879 g/mL at 20 °C (lit.)

應用

pharmaceutical (small molecule)

形式

neat

儲存溫度

2-30°C

SMILES 字串

Cc1ccccc1C

InChI

1S/C8H10/c1-7-5-3-4-6-8(7)2/h3-6H,1-2H3

InChI 密鑰

CTQNGGLPUBDAKN-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

o-Xylene is a nonoxygenated, homocyclic aromatic compound that occurs as a constituent of petroleum. It belongs to the class of volatile organic compounds (VOCs) having vapor pressure high enough to vaporize under normal conditions and enter into the atmosphere. It is found to be relatively water-soluble and suspected to have carcinogenic properties.
Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.

應用

These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

分析報告

These secondary standards offer multi-traceability to the USP, EP (PhEur) and BP primary standards, where they are available.

其他說明

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

腳註

To see an example of a Certificate of Analysis for this material enter LRAB8972 in the slot below. This is an example certificate only and may not be the lot that you receive.

推薦產品

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

訊號詞

Danger

危險分類

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Asp. Tox. 1 - Eye Irrit. 2 - Flam. Liq. 3 - Skin Irrit. 2 - STOT SE 3

標靶器官

Respiratory system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

89.6 °F - closed cup

閃點(°C)

32.0 °C - closed cup


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

其他客户在看

Anaerobic degradation of toluene and o-xylene by a methanogenic consortium.
Edwards EA and Grbic-Galic D
Applied and Environmental Microbiology, 60(1), 313-322 (1994)
Separation and determination of benzene, toluene, ethylbenzene and o-xylene compounds in water using directly suspended droplet microextraction coupled with gas chromatography-flame ionization detector.
Sarafraz-Yazdi, et al.
Talanta, 78(3), 936-941 (2009)
Casper Bindzus Foldager et al.
Cartilage, 5(2), 123-132 (2014-04-01)
The objective of the present study was to investigate the presence and distribution of 2 basement membrane (BM) molecules, laminin and collagen type IV, in healthy and degenerative cartilage tissues. Normal and degenerated tissues were obtained from goats and humans
Olivier Alluin et al.
PloS one, 9(10), e111072-e111072 (2014-10-29)
While several cellular and pharmacological treatments have been evaluated following spinal cord injury (SCI) in animal models, it is increasingly recognized that approaches to address the glial scar, including the use of chondroitinase ABC (ChABC), can facilitate neuroanatomical plasticity. Moreover
Pawaree Saisawat et al.
Kidney international, 85(6), 1310-1317 (2013-10-25)
Congenital abnormalities of the kidney and urinary tract (CAKUT) account for approximately half of children with chronic kidney disease and they are the most frequent cause of end-stage renal disease in children in the US. However, its genetic etiology remains

实验方案

ASTM D6526: GC Analysis of Impurities in Toluene on SLB®-IL100, 60 m Column

Protocol for HPLC Analysis of Xylene Isomers on Discovery® Zr-Carbon

GC Analysis of Xylene Isomers on SLB®-IL60 - The cresol (methylphenol) isomers are also precursors to many chemicals. This chromatogram of a mix of aromatic and methylphenol compounds was generated using an SLB-IL60 ionic liquid column. Its interaction mechanisms allow the separation of all three xylene isomers, and all three cresol isomers.

Technical article page on -US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on Equity®-1 after Purge & Trap using "M" Trap

查看所有结果

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门