跳转至内容
Merck
所有图片(1)

文件

GCYT1-16K

Millipore

MILLIPLEX® Chicken Cytokine/Chemokine Panel 1 - Immunology Multiplex Assay

登录查看公司和协议定价


About This Item

分類程式碼代碼:
12161503
NACRES:
NA.47

物種活性

chicken

製造商/商標名

Milliplex®

assay range

accuracy: 87-100%
(using the overnight protocol)

accuracy: 95-100%
(using the 2 hour protocol)

standard curve range: 12.21-20,000 pg/mL
(for RANTES)

standard curve range: 122.1-500,000 pg/mL
(for IL-6)

standard curve range: 18.3-75,000 pg/mL
(for IFNγ)

standard curve range: 18.3-75,000 pg/mL
(for MIP-3α)

standard curve range: 24.4-100,000 pg/mL
(for IL-10)

standard curve range: 3.66-15,000 pg/mL
(for IFNα)

standard curve range: 36.6-150,000 pg/mL
(for IL-21)

standard curve range: 4.88-20,000 pg/mL
(for MIP-1β)

standard curve range: 4.88-20,000 pg/mL
(for VEGF)

standard curve range: 48.8-200,000 pg/mL
(for IL-2)

standard curve range: 7.32-30,000 pg/mL
(for IL-16)

standard curve range: 9.75-40,000 pg/mL
(for M-CSF)

inter-assay cv: <20%
intra-assay cv: <10%

技術

multiplexing: suitable

檢測方法

fluorometric (Luminex® xMAP®)

運輸包裝

wet ice

儲存溫度

2-8°C

一般說明

Inflammation and immune cell response are key to maintaining homeostasis. The more we understand the mechanisms of disease, the more we discover the role that inflammation plays in the etiology of disease. This is as true for chicken as it is for humans. Both experience immunological diseases, such as infectious disease, osteoarthritis and respiratory disease, as well as neurologic, metabolic and cardiovascular disease and even cancer. However, until now the ability to measure levels of cytokines and chemokines in chicken has been limited primarily to ELISAs. Researchers now have the ability to measure multiple inflammation biomarkers simultaneously using EMD Millipore′s MILLIPLEX® Chicken Cytokine/Chemokine Panel 1, based on the Luminex® xMAP® technology.

EMD Millipore′s MILLIPLEX® Chicken Cytokine/Chemokine Panel is a 12-plex kit to be used for the simultaneous quantification of any or all of the following analytes in chicken serum, plasma and PBMC samples: Interferon alpha (IFNα), Interferon gamma (IFNγ), Interleukin 2 (IL-2), Interleukin 6 (IL-6), Interleukin 10 (IL-10), Interleukin 16 (IL-16), Interleukin 21 (IL-21), Macrophage Inflammatory protein-1β (MIP-1b), Macrophage Inflammatory protein-3 (MIP-3a), RANTES (regulated on activation, normal T cell expressed and secreted), Macrophage colony-stimulating factor (M-CSF), Vascular endothelial growth factor (VEGF).
Note: The protocol recommends a 1:4 dilution of serum and plasma samples.

MILLIPLEX® offers the broadest selection of analytes across a wide range of disease states and species. Once the analytes of interest have been identified, you can rely on the quality that we build into each kit to produce results you can trust. In addition to the assay characteristics listed in the protocol, other performance criteria evaluated during the verification process include: cross-reactivity, dilution linearity, kit stability, and sample behavior (e.g. detectability and stability). In addition each panel and kit meets stringent manufacturing criteria to ensure batch-to-batch reproducibility.

Each MILLIPLEX® panel and kit includes:
  • Quality controls (QCs) to qualify assay performance
  • Comparison of standard (calibrator) and QC lots to a reference lot to ensure lot-to-lot consistency
  • Optimized serum matrix to mimic native analyte environment in serum and plasma samples
  • Detection antibody cocktails designed to yield consistent analyte profiles within panel

The MILLIPLEX® Chicken Cytokine/Chemokine Panel thus enables you to focus on the therapeutic potential of cytokines and chemokines.

特異性

Cross Reactivity:
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.

應用

The Chicken Cytokine/Chemokine bead-based multiplex cytokine panel, using the Luminex® xMAP® technology, enables the simultaneous analysis of 12 cytokine and chemokine biomarkers in chicken serum, plasma and cell culture samples.

  • This assay may be run overnight (16-18 hours) at 2-8°C or for 2 hours at room temperature (20-25°C) with agitation on a plate shaker.
  • A maximum of 25 μL per well 1:4 serum or plasma diluted in Serum Matrix should be used for all analytes. Tissue culture supernatants may require dilution in appropriate control medium. Tissue/cell extracts should be prepared in neutral buffers containing reagents and conditions that do not interfere with assay performance.

Analytes Available:
  • IL-16
  • IFN-α
  • IFNγ
  • IL-10
  • IL-21
  • IL-2
  • M-CSF
  • IL-6
  • MIP-3α
  • MIP-1β
  • RANTES
  • VEGF

Research Category:
  • Inflammation & Immunology

Research Sub-Category:
  • Inflammation & Autoimmune Mechanisms
  • Inflammation
  • Infectious Diseases
  • Cytokines & Cytokine Receptors
  • Oncology
  • Obesity
  • Metabolic Disorders

特點和優勢

Design your multiplex kit by choosing available analytes within this panel.

包裝

96 well plate

分析報告

The protocol recommends a 1:4 dilution of serum and plasma samples.

法律資訊

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

訊號詞

Danger

危險分類

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

標靶器官

Respiratory Tract

儲存類別代碼

10 - Combustible liquids


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门