Supelco

JWH-018 4-Hydroxypentyl metabolite-D5 (indole-D5) solution

100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

别名:

JWH-018 4-Hydroxypentyl metabolite-d5 (indole-d5)

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C24H18D5NO2
分子量:
362.48
EC號碼:
分類程式碼代碼:
41116107
NACRES:
NA.24

等級

certified reference material

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

drug control

Narcotic Licence Schedule D (Switzerland)

濃度

100 μg/mL in methanol

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

forensics and toxicology
forensics and toxicology

格式

single component solution

儲存溫度

−20°C

InChI

1S/C24H23NO2/c1-17(26)8-7-15-25-16-22(20-12-4-5-14-23(20)25)24(27)21-13-6-10-18-9-2-3-11-19(18)21/h2-6,9-14,16-17,26H,7-8,15H2,1H3/i4D,5D,12D,14D,16D

InChI 密鑰

LLFBQQHYZJTRAS-NXZSVEOISA-N

一般說明

A stable-labeled internal standard of JWH-018 4-Hydroxypentyl metabolite, also known as the Omega minus one-OH metabolite of JWH-018. The 4-Hydroxypentyl analog is the major urinary metabolite of JWH-018, a synthetic cannabinoid found in the herbal mixture Spice.

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

相關產品

产品编号
说明
价格

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 1

閃點(°F)

49.5 °F - closed cup

閃點(°C)

9.7 °C - closed cup


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

商品

LC-MS/MS is a powerful tool that brings numerous benefits to the clinical sample analysis arena. However, due to the complexity of the instrumentation there are some unique challenges that also accompany these benefits. Even following sample extraction and cleanup, matrix effects from the samples can cause interferences or impact ionization efficiency.

LC-MS/MS is a powerful tool that brings numerous benefits to the clinical sample analysis arena. However, due to the complexity of the instrumentation there are some unique challenges that also accompany these benefits. Even following sample extraction and cleanup, matrix effects from the samples can cause interferences or impact ionization efficiency.