跳转至内容
Merck

M-108

Supelco

MTBSTFA

with 1% t-BDMCS, ampule of 5 × 1 mL, analytical standard, Cerilliant®

别名:

N-叔丁基二甲基甲硅烷基-N-甲基三氟乙酰胺,含 1% 叔丁基二甲基氯硅烷, N-甲基-N-叔丁基二甲基甲硅烷基三氟乙酰胺, MTBSTFA + 1% TBDMSCl, 甲硅烷基化混合物VI

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C9H18F3NOSi
CAS号:
分子量:
241.33
Beilstein:
3606546
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:

产品名称

MTBSTFA(含 1%t-BDMCS), (with 1% t-BDMCS), ampule of 5 × 1 mL, analytical standard, Cerilliant®

等級

analytical standard

品質等級

反應適用性

reagent type: derivatization reagent
reaction type: Acylations

包裝

ampule of 5 × 1 mL

製造商/商標名

Cerilliant®

技術

gas chromatography (GC): suitable

應用

forensics and toxicology

形式

neat

儲存溫度

−20°C

SMILES 字串

CN(C(=O)C(F)(F)F)[Si](C)(C)C(C)(C)C

InChI

1S/C9H18F3NOSi/c1-8(2,3)15(5,6)13(4)7(14)9(10,11)12/h1-6H3

InChI 密鑰

QRKUHYFDBWGLHJ-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

應用


  • Pharmaceutical substances in ambient particulates: A preliminary assessment.: This study explores the presence of pharmaceutical compounds in environmental particulate matter, using analytical methods that could involve derivatization agents like MTBSTFA. The detection of these substances in air samples suggests potential health impacts and environmental persistence (Cecinato et al., 2017) (Cecinato et al., 2017).


法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany

象形圖

FlameExclamation mark

訊號詞

Warning

危險聲明

危險分類

Eye Irrit. 2 - Flam. Liq. 3 - Skin Irrit. 2

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

113.0 °F - closed cup

閃點(°C)

45 °C - closed cup


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

抱歉,我们目前尚未线上提供该产品的COA。

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Xiaodong Huang et al.
Analytical chemistry, 80(1), 107-114 (2007-12-07)
This work describes an approach to differential metabolomics that involves stable isotope labeling for relative quantification as part of sample analysis by two-dimensional gas chromatography/mass spectrometry (GCxGC/MS). The polar metabolome in control and experimental samples was extracted and differentially derivatized
Claude Schummer et al.
Talanta, 77(4), 1473-1482 (2008-12-17)
In this study, MTBSTFA and BSTFA, which are among the preferred derivatization reagents for silylation were both tested on derivatization of six different groups of polar chemicals to get information about usefulness in terms of sensitivity and specificity of both
A Royer et al.
Journal of chromatography. A, 1108(1), 129-135 (2006-01-31)
An analytical method has been developed for the determination of residues of ethephon (2-chloroethyl phosphonic acid) in drinking and surface water. The procedure is based on de-ionisation with an anion/cation-exchange resin, solid phase extraction by means of anion-exchange polystyrene-divinylbenzene extraction
Xiaowei Wang et al.
Analytica chimica acta, 753, 57-63 (2012-10-31)
A sample preparation method for the determination of hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) in sediment samples was developed using gas chromatography-mass spectrometry (GC-MS). Dispersive liquid-liquid microextraction (DLLME) with derivatization was performed following the subcritical water extraction (SWE) that provided which
Man-Jeong Paik et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 821(1), 94-104 (2005-05-17)
Simultaneous profiling analysis of urinary amino acids (AAs) and carboxylic acids (CAs) was combined with retention index (I) analysis for graphic recognition of abnormal metabolic state. The temperature-programmed I values of the AA and CA standards measured as ethoxycarbonyl (EOC)/methoxime

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门