跳转至内容
Merck

392537

Sigma-Aldrich

氧化钐(III)

99.99% trace metals basis

别名:

Samaria

登录查看公司和协议定价


About This Item

线性分子式:
Sm2O3
CAS号:
EC號碼:
MDL號碼:
分類程式碼代碼:
12352300
PubChem物質ID:
NACRES:
NA.23

化驗

99.99% trace metals basis

形狀

powder

反應適用性

reagent type: catalyst
core: samarium

密度

8.35 g/mL at 25 °C (lit.)

SMILES 字串

O=[Sm]O[Sm]=O

InChI

1S/3O.2Sm

InChI 密鑰

PRCWVHVINXAFRG-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

儲存類別代碼

10 - Combustible liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

Not applicable

閃點(°C)

Not applicable


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

H M T U Herath et al.
Journal of biomedical materials research. Part A, 94(1), 130-136 (2010-02-04)
The biocompatibility of natural samarium (III) oxide, which has previously been used for treatment in bone-related diseases was determined as a first step in its evaluation as a bone implant material. Assessment for 28 days using osteoblast-like cells revealed no
Guohui Zhang et al.
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine, 67(1), 46-49 (2008-08-19)
Cross sections of the (147)Sm(n, alpha)(144)Nd reaction were measured at En=5.0 and 6.0MeV. A twin gridded ionization chamber was used as a charged particle detector and two large area (147)Sm(2)O(3) samples placed back to back were employed. Experiments were performed
Matthew D Burke et al.
Pharmaceutical research, 24(4), 695-704 (2007-03-21)
To develop a robust radiolabeling technique to enable evaluation of difficult to radiolabel gastric retentive formulations using gamma scintigraphy. The use of a successful radiolabel will allow accurate assessment of the gastric residence time of the formulations. The retention of
Janne Marvola et al.
International journal of pharmaceutics, 281(1-2), 3-10 (2004-08-04)
This paper is a report from a pharmacoscintigraphic study with an Egalet constant-release system containing caffeine and natural abundance samarium oxide. First the formulation was tested in vitro to clarify integrity during irradiation in the nuclear reactor. Then six healthy
B Mandal et al.
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 60(4), 933-939 (2004-03-24)
Microphone based photoacoustic (PA) spectrometer to study solids in powder form was designed and fabricated. Laser PA spectra of Sm3+ ion in Sm2O3 and SmCl3.6H2O microcrystalline powders were recorded first time in 484-542 nm spectral region at room temperature. Analysis

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门