53822-U
Ascentis® Express 90 Å C18 (2.7 μm) HPLC Columns
L × I.D. 5 cm × 2.1 mm, HPLC Column
Synonyme(s) :
Core-shell (SPP) Fused Core C18 HPLC column
About This Item
Produits recommandés
product name
Colonne de CLHP Ascentis® Express C18, 2,7 μm, 2.7 μm particle size, L × I.D. 5 cm × 2.1 mm
Matériaux
stainless steel column
Agence
suitable for USP L1
Gamme de produits
Ascentis®
Caractéristiques
endcapped
Fabricant/nom de marque
Ascentis®
Conditionnement
1 ea of
Paramètres
60 °C temp. range
600 bar max. pressure (9000 psi)
Technique(s)
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
L × D.I.
5 cm × 2.1 mm
Superficie
135 m2/g
Impuretés
<5 ppm metals
Matrice
Fused-Core particle platform
superficially porous particle
Groupe de la matrice active
C18 (octadecyl) phase
Taille des particules
2.7 μm
Dimension de pores
90 Å
pH de fonctionnement
2-9
Application(s)
food and beverages
Technique de séparation
reversed phase
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Catégories apparentées
Description générale
Rendez-vous sur la page d′accueil Ascentis Express pour obtenir plus d′informations sur cette nouvelle technologie de colonne.
Application
Analyse UHPLC/MS de l′huile de maïs sur l′Ascentis® Express C30 par comparaison à l′Ascentis®Express C18
Analyse CLHP du paracétamol et des impuretés \sur l′Ascentis®Express C18, 2,7 μm
Analyse CLHP des parabènes sur l′Ascentis®Express C18, 2,7 μm
Informations légales
Application
Colonne de garde
Produit(s) apparenté(s)
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
Vous ne trouvez pas la bonne version ?
Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Articles
In this report, we demonstrated the extraction of SupelMIP SPE – Clenbuterol method against a published hydrophilic polymer SPE method for the trace extraction of clenbuterol from urine for subsequent LC-MS-MS analysis.
Improved LC/MS Detection of Estradiol using 4-(Dimethylamino) benzoyl chloride (DMABC) derivatization agent relative to dansyl chloride.
Accurate protein binding affinities were measured using bioSPME more rapidly than membrane dialysis (RED) techniques. Binding affinities correlated to the reference values.
Select HLB SPE is a hydrophilic polymer phase for analyte extraction from aqueous matrices. Here it’s used for statins in plasma and 48 pharmaceutical analytes in drinking water.
Protocoles
We presents a robust method for analyzing 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in serum using a multiplexed LC-MS-MS system.
A highly selective and sensitive analytical method was developed for chloramphenicol using a QuEChERS type sample preparation approach and LC-MS/MS detection.
Fast method for the cleanup, analysis, and quantification of aflatoxin M1 in milk samples to EU regulatory standards (0.025 μg/kg).
Separation of Lutein, analytical standard
Chromatograms
application for SPE, application for LC-MSapplication for SPE, application for LC-MSapplication for HPLCapplication for HPLCAfficher plusNotre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique