Saltar al contenido
Merck

06699

Sigma-Aldrich

Atto 532

BioReagent, suitable for fluorescence, ≥90% (HPCE)

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Número MDL:
Código UNSPSC:
12352108
NACRES:
NA.25

Línea del producto

BioReagent

Nivel de calidad

Análisis

≥90% (HPCE)

fabricante / nombre comercial

ATTO-TEC GmbH

fluorescencia

λex 533 nm; λem 560 nm in 0.1 M phosphate pH 7.0

idoneidad

suitable for fluorescence

temp. de almacenamiento

−20°C

Descripción general

Atto 532 hat eine molekulare Absorption von 115.000 und eine Quantenausbeute von 90% in Wasser, so dass er starke Fluoreszenz zeigt.
Die Abklingzeit der Fluoreszenz beträgt 3.8 ns.

Aplicación

Atto fluorescent labels are designed for high sensitivity applications, including single molecule detection. Atto labels have rigid structures that do not show any cis-trans-isomerization. Thus these labels display exceptional intensity with minimal spectral shift on conjugation.
Atto 532 has been conjugated with the secondary antibodies for STED (stimulated emission depletion) microscopy and immunofluorescence studies.

Información legal

This product is for Research use only. In case of intended commercialization, please contact the IP-holder (ATTO-TEC GmbH, Germany) for licensing.

Código de clase de almacenamiento

11 - Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable

Equipo de protección personal

Eyeshields, Gloves, type N95 (US)


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Uffe V Schneider et al.
BMC biotechnology, 10, 4-4 (2010-01-28)
Melting temperature of DNA structures can be determined on the LightCycler using quenching of FAM. This method is very suitable for pH independent melting point (Tm) determination performed at basic or neutral pH, as a high throughput alternative to UV
3D reconstruction of high-resolution STED microscope images.
Punge A et al.
Microscopy Research and Technique, 71, 644-644 (2008)
Andrea Armbrüster et al.
FEBS letters, 579(9), 1961-1967 (2005-03-29)
The ability of subunit C of eukaryotic V-ATPases to bind ADP and ATP is demonstrated by photoaffinity labeling and fluorescence correlation spectroscopy (FCS). Quantitation of the photoaffinity and the FCS data indicate that the ATP-analogues bind more weakly to subunit
Daniel Aquino et al.
Nature methods, 8(4), 353-359 (2011-03-15)
We demonstrate three-dimensional (3D) super-resolution imaging of stochastically switched fluorophores distributed across whole cells. By evaluating the higher moments of the diffraction spot provided by a 4Pi detection scheme, single markers can be simultaneously localized with <10 nm precision in
SERRS-based detection of dye-labeled DNA using positively-charged Ag nanoparticles.
Gill, R. and Lucassen, G. W.
Analytical Methods : Advancing Methods and Applications, 2, 445-447 (2010)

Artículos

Fluorescence lifetime measurement is advantageous over intensity-based measurements. Applications include fluorescence lifetime assays, sensing and FLI.

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico