Saltar al contenido
Merck

E-071

Supelco

Ethylone hydrochloride

1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®

Sinónimos:

Ethylone hydrochloride solution

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C12H15NO3 · HCl
Peso molecular:
257.71
Número CE:
Número MDL:
Código UNSPSC:
41116107
NACRES:
NA.24

grado

certified reference material

Nivel de calidad

Formulario

liquid

Características

Snap-N-Spike®/Snap-N-Shoot®

envase

ampule of 1 mL

fabricante / nombre comercial

Cerilliant®

drug control

Narcotic Licence Schedule E (Switzerland); psicótropo (Spain); Decreto Lei 15/93: Tabela IIA (Portugal)

concentración

1.0 mg/mL in methanol (as free base)

técnicas

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

aplicaciones

forensics and toxicology

Formato

single component solution

temp. de almacenamiento

−20°C

cadena SMILES

Cl.N(C(C)C(=O)c1cc2c(cc1)OCO2)CC

InChI

1S/C12H15NO3.ClH/c1-3-13-8(2)12(14)9-4-5-10-11(6-9)16-7-15-10;/h4-6,8,13H,3,7H2,1-2H3;1H

Clave InChI

FQUJUYOEUQPDDR-UHFFFAOYSA-N

Descripción general

Also known as bk-MDEA or 3,4-methylenedioxy-N-ethylcathinone, ethylone is a designer drug of the amphetamine and cathinone classes with cases of abuse reported in Europe. This certified solution standard is suitable for numerous GC/MS and LC/MS applications from clinical toxicology testing and forensic analysis to urine drug testing.

Información legal

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

Palabra de señalización

Danger

Clasificaciones de peligro

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

Órganos de actuación

Eyes

Código de clase de almacenamiento

3 - Flammable liquids

Clase de riesgo para el agua (WGK)

WGK 1

Punto de inflamabilidad (°F)

49.5 °F - closed cup

Punto de inflamabilidad (°C)

9.7 °C - closed cup


Listados normativos

Los listados normativos se proporcionan para los productos químicos principalmente. Para los productos no químicos sólo se puede proporcionar información limitada. Si no hay ninguna entrada, significa que ninguno de los componentes está en la lista. Es obligación del usuario garantizar el uso seguro y legal del producto.

EU REACH Annex XVII (Restriction List)

CAS No.

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Artículos

As new “bath salt” drugs such as methylone, ethylone, mephedrone, butylone and other methcathinone analogs increase in popularity, toxicologists require native and labeled certified reference materials to accurately identify and quantify the new compounds in patient samples.

The combination of ion-exchange SPE with the HILIC HPLC separation provides a novel approach for the testing of problematic bath salt compounds.

LC-MS/MS is a powerful tool that brings numerous benefits to the clinical sample analysis arena. However, due to the complexity of the instrumentation there are some unique challenges that also accompany these benefits. Even following sample extraction and cleanup, matrix effects from the samples can cause interferences or impact ionization efficiency.

Protocolos

Separation of 3,4-Methylenedioxypyrovalerone HCl (MDPV) solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Buphedrone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; 3-Fluoromethcathinone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Butylone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Ethylone hydrochloride, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; 4-Fluoromethcathinone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Mephedrone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Methylone hydrochloride, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Methedrone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material

Chromatograms

application for HPLC

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico