25420-U
Colonna GC capillare SPB®-5
L × I.D. 30 m × 0.53 mm, df 1.00 μm
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Materiali
fused silica
Livello qualitativo
agenzia
meets requirements for USP G27 and G36
Parametri
-60-300 °C temperature (isothermal)
-60-320 °C temperature (programmed)
Beta
133
df
1.00 μm
tecniche
gas chromatography (GC): suitable
Lungh. × D.I.
30 m × 0.53 mm
Gruppo funzionale matrice
Bonded; poly(5% diphenyl/95% dimethyl siloxane) phase
Tipo di colonna
capillary non-polar
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
Descrizione generale
Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column.
Applicazione: Questa colonna non polare per scopi generali offre principalmente un ordine di eluizione secondo il punto di ebollizione con un piccolo aumento di selettività, specialmente per i composti aromatici.
Codice USP: questa colonna soddisfa i requisiti USP G27 e G36.
Fase
Codice USP: questa colonna soddisfa i requisiti USP G27 e G36.
Fase
- Legata
- Poli (5% difenile/95% dimetilsilossano)
- ≤D. I. 0,32 mm, <2 μm: da -60 °C a 320 °C (isoterma o programmata)
- ≤D. I. 0,32 mm, ≥2 μm: da -60 °C a 300 °C (isoterma o programmata)
- ≥D. I. 0,53 mm, <2 μm: da -60 °C a 300 °C (isoterma) o 320 °C (programmata)
- ≥D. I. 0,53 mm, ≥2 μm: da -60 °C a 260 °C (isoterma) o 280 °C (programmata)
Applicazioni
SPB®-5 Capillary GC Column may be used as stationary phase for determination of nivalenol and deoxynivalenol in cereals by electron-capture gas chromatography.
Altre note
We offer a variety of chromatography accessories including analytical syringes
Note legali
SPB is a registered trademark of Merck KGaA, Darmstadt, Germany
Scegli una delle versioni più recenti:
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Determination of nivalenol and deoxynivalenol in cereals by electron-capture gas chromatography.
Journal - Association of Official Analytical Chemists, 69 (5), 889-893 (1985)
Forensic science international, 46(3), 169-180 (1990-07-01)
Positive-ion electron impact (PIEI), positive-ion chemical ionization (PICI) and negative-ion chemical ionization (NICI) mass spectra of 9 carbamate pesticides are presented. In the PIEI mode, the spectra showed small molecular peaks, intense or base peaks due to M - CH3NHCO
Journal of chromatography. A, 985(1-2), 211-220 (2003-02-13)
The sterol composition of extra virgin olive oil is very characteristic and, thus, has become a helpful tool to detect adulterations with other vegetable oils. Special attention has been addressed to the separate determination of the free and esterified sterol
Talanta, 106, 14-19 (2013-04-20)
4-Methylsterols and 4,4-dimethylsterols of 47 samples of subcutaneous fat from Iberian pigs reared on two different fattening systems, "Extensive" and "Intensive", have been analyzed by GC-MS and GC-FID. The lipids were extracted by melting the subcutaneous fat in a microwave
Development of a passive sampler to measure personal exposure to gaseous PAHs in community settings.
Environmental science & technology, 40(19), 6051-6057 (2006-10-21)
A sensitive, simple, and cost-effective passive sampling methodology was developed to quantify personal exposure to gaseous polycyclic aromatic hydrocarbons (PAHs). A Fan-Lioy passive PAH sampler (FL-PPS) is constructed from 320 sections of 1-cm long SPB-5 GC columns (0.75-mm i.d. and
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.