ZFA100001
A10® TOC Monitor
suitable for water monitoring
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Codice UNSPSC:
41104200
eCl@ss:
33050190
NACRES:
NA.21
Prodotti consigliati
Confezionamento
pkg of 1 unit
applicazioni
water monitoring
Condizioni di spedizione
ambient
Descrizione generale
A10® TOC Monitor can be used for the accurate online measurement of total organic carbon (TOC) content in ultrapure water delivered by Milli-Q® water purification systems without a built-in TOC monitor. It is compatible with any high purity water laboratory system.
Applicazioni
A10® TOC Monitor is an ideal accessory for use in water monitoring. It is reported for use in the measurement of TOC/organic content in purified water and in water used as eluent in LC-MS studies.
Caratteristiche e vantaggi
- High accuracy enabled by complete oxidation of organics to their end-point reaction, attributed to oxidation and conductivity measurements occurring within the same cell.
- Range (1 – 999) and precision passing USP & EP suitability tests according to Milli-Q® Quality Assurance System standard procedures and specifications.
- Traceability of measurement equipment is performed as per the Milli-Q® Calibration System. Certification of calibration is provided to comply with the industry requirements. A10® TOC Monitor can be recalibrated at user request and has been designed to take into account the suitability test requirements as specified in USP <643>.
Note legali
A10 is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
P W M H Smeets et al.
Water research, 40(17), 3239-3248 (2006-08-30)
To determine the disinfection efficacy of ozonation, water companies can apply several disinfection calculation methods. The goal of this study was to evaluate the use of the T10 and continuous stirred tank reactor (CSTR) method to extrapolate inactivation rates of
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.