Passa al contenuto
Merck
Tutte le immagini(1)

Key Documents

HKI5MAG-99K

Millipore

MILLIPLEX® Human Kidney Injury Magnetic Bead Panel 5 - Toxicity Multiplex Assay

The analytes available for this multiplex kit are: α-1-Microglobulin, Collagen IV, Lipocalin-2/NGAL, Osteoactivin, TIMP-1, Uromodulin.

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
12161503
eCl@ss:
32161000

Livello qualitativo

Reattività contro le specie

human

Produttore/marchio commerciale

Milliplex®

assay range

accuracy: 62-90%
intra-assay cv: <10
sensitivity: 0.05-0.56 ng/mL
(MinDC+2SD)

standard curve range: 0.05-50 ng/mL
(Lipocalin-2/NGAL)

standard curve range: 0.05-50 ng/mL
(Uromodulin)

standard curve range: 0.10-100 ng/mL
(TIMP-1)

standard curve range: 0.20-200 ng/mL
(Osteoactivin)

standard curve range: 0.24-250 ng/mL
(α-1-Microglobulin)

standard curve range: 0.49-500 ng/mL
(Collagen IV)

tecniche

multiplexing: suitable

Metodo di rivelazione

fluorometric (Luminex xMAP)

Condizioni di spedizione

wet ice

Descrizione generale

Maintenance of physiological balance in the body is attributed in part to normal kidney function. Altered kidney function due to injury, drug toxicity or kidney failure may be life threatening. Toxicity is the leading cause of drug failure, so research is expanding in search of more sensitive, rapid methods to determine organ-specific damage as quickly as possible. Traditionally, blood urea nitrogen (BUN) and serum creatinine tests have been used to determine drug-induced damage to the kidney. These tests only detect kidney damage after it begins and do not allow for the elucidation of where in the kidney the damage has occurred. Specificity and earlier detection of kidney injury is vital, and this area of research is expanding in search of more sensitive, rapid methods for determining the specific area of damage in kidney.

The MILLIPLEX® portfolio provides valuable research assays to investigate multiple biomarkers of kidney injury in human serum and plasma samples using the Luminex® xMAP® instrument platform.

The MILLIPLEX® Human Kidney Injury Bead Panel 5 contains all the components necessary to measure the following six biomarkers in any combination using Luminex® xMAP® technology: α-1-Microglobulin, Collagen IV, Lipocalin-2/NGAL, Osteoactivin, TIMP-1, Uromodulin. The kit uses a 96-well format, contains a lyophilized standard cocktail, two quality controls and can measure up to 38 serum or plasma samples in duplicate.

Panel Type: Toxicity

Specificità

There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.

Applicazioni

  • Analytes: α-1-Microglobulin, Collagen IV, Lipocalin-2/NGAL, Osteoactivin, TIMP-1, Uromodulin
  • Recommended Sample type: serum and plasma
  • Recommended Sample dilution: 1:75 in kit Assay Buffer. Customers should determine the optimal dilution factor for their samples. Our recommendations are based on serum and plasma samples from normal subjects
  • Assay Run Time: Overnight
  • Research Category: Inflammation & Immunology

Caratteristiche e vantaggi

Design your multiplex kit by choosing available analytes within this panel.

Confezionamento

Everything you need in a single kit.

Stoccaggio e stabilità

Recommended storage for kit components is 2 - 8°C.

Altre note

Please contact Technical Service for linearity of dilution.
Sensitivity: Please see kit protocol for individual assay sensitivities.

Note legali

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Esclusione di responsabilità

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Avvertenze

Danger

Classi di pericolo

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

Organi bersaglio

Respiratory Tract

Codice della classe di stoccaggio

6.1C - Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Classe di pericolosità dell'acqua (WGK)

WGK 3


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Contenuto correlato

Novel kidney toxicity biomarkers expand options for acute nephrotoxicity detection. Multiplex assays measure multiple renal damage biomarkers in small sample volumes, minimizing time and costs. See how MILLIPLEX® multiplex kidney toxicity assays detected vancomycin-induced subacute nephrotoxicity in rat models.

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.