320145

Sigma-Aldrich

Hydroxyde d′ammonium solution

ACS reagent, 28.0-30.0% NH3 basis

Synonyme(s) :

Ammoniaque

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
NH4OH
Numéro CAS:
Poids moléculaire :
35.05
Numéro Beilstein :
3587154
Numéro MDL:
Code UNSPSC :
12352106
eCl@ss :
38060103
ID de substance PubChem :

Qualité

ACS reagent

Densité de vapeur

1.2 (vs air)

Pression de vapeur

115 mmHg ( 20 °C)

Forme

liquid

Limite d'explosivité

27 %

Concentration

28.0-30.0% NH3

Impuretés

MnO4- reducers, passes test
≤0.002% CO2

Résidus de calcination

≤0.002%

Densité

0.9 g/mL at 25 °C (lit.)

Traces d'anions

chloride (Cl-): ≤0.5 ppm
nitrate (NO3-): ≤2 ppm
phosphate (PO43-): ≤2 ppm
sulfate (SO42-): ≤2 ppm

Traces de cations

Fe: ≤0.2 ppm
heavy metals (as Pb): ≤0.5 ppm

Chaîne SMILES 

[NH4+].[OH-]

InChI

1S/H3N.H2O/h1H3;1H2

Clé InChI

VHUUQVKOLVNVRT-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Pictogrammes

CorrosionExclamation markEnvironment

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1 - Skin Corr. 1 - STOT SE 3

Organes cibles

Respiratory system

Code de la classe de stockage

8B - Non-combustible corrosive hazardous materials

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Courtney R Sullivan et al.
Molecular neurobiology, 56(6), 4492-4517 (2018-10-20)
We utilized a cell-level approach to examine glycolytic pathways in the DLPFC of subjects with schizophrenia (n = 16) and control (n = 16) and found decreased mRNA expression of glycolytic enzymes in pyramidal neurons, but not astrocytes. To replicate these novel bioenergetic findings
Konstantin Chingin et al.
Analytical chemistry, 84(15), 6856-6862 (2012-07-12)
We introduce an online multiple-junction capillary isoelectric focusing fractionator (OMJ-CIEF) for separation of biological molecules in solution by pI. In OMJ-CIEF, the separation capillary is divided into seven equal sections joined with each other via tubular Nafion membrane insertions. Each
Ciceron Ayala-Orozco et al.
ACS nano, 8(6), 6372-6381 (2014-06-04)
Au nanoparticles with plasmon resonances in the near-infrared (NIR) region of the spectrum efficiently convert light into heat, a property useful for the photothermal ablation of cancerous tumors subsequent to nanoparticle uptake at the tumor site. A critical aspect of
Enrique Cequier et al.
Analytica chimica acta, 845, 98-104 (2014-09-10)
Organophosphate triesters are common flame retardants used in a wide variety of consumer products from which they can migrate and pollute the indoor environment. Humans may thus be continuously exposed to several organophosphate triesters which might be a risk for
Aurélie Periat et al.
Journal of chromatography. A, 1356, 211-220 (2014-07-16)
In this study, the influence of electrospray ionization (ESI) source design on the overall sensitivity achieved in hydrophilic interaction chromatography (HILIC) and reversed phase liquid chromatography (RPLC), was investigated. State-of-the-art triple quadrupole mass analyzers from AB Sciex, Agilent Technologies and

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique