  • Hydrophilic interaction chromatography versus reversed phase liquid chromatography coupled to mass spectrometry: effect of electrospray ionization source geometry on sensitivity.

Hydrophilic interaction chromatography versus reversed phase liquid chromatography coupled to mass spectrometry: effect of electrospray ionization source geometry on sensitivity.

Journal of chromatography. A (2014-07-16)
Aurélie Periat, Isabelle Kohler, Aurélie Bugey, Stefan Bieri, François Versace, Christian Staub, Davy Guillarme
RÉSUMÉ

In this study, the influence of electrospray ionization (ESI) source design on the overall sensitivity achieved in hydrophilic interaction chromatography (HILIC) and reversed phase liquid chromatography (RPLC), was investigated. State-of-the-art triple quadrupole mass analyzers from AB Sciex, Agilent Technologies and Waters equipped with brand specific source geometries were tested with various mobile phase pH on 53 pharmaceutical compounds. The design of the ESI source showed to strongly influence the gain in sensitivity that can be achieved in HILIC compared to RPLC mode. The 6460 Triple Quadrupole LC/MS system from Agilent Technologies was particularly affected by mobile phase settings. Indeed, compared to RPLC conditions, 92% of the compounds had an increased signal-to-noise ratio at a flow rate of 300 μL/min in HILIC mode at pH 6, while this percentage dropped to only 7% at 1000 μL/min and pH 3. In contrast, the influence of flow rate and mobile phase pH on the gain in sensitivity between RPLC and HILIC was found very limited with the API 5000 LC/MS/MS system from AB Sciex, as only 15 to 36% of the tested compounds showed an enhanced sensitivity in HILIC mode. With the Xevo TQ-S instrument from Waters, superior sensitivity in HILIC was noticed for 85% of the compounds with optimal conditions (i.e., pH 3 and 1000 μL/min), whereas at sub-optimal conditions (i.e. pH 6 and 300 μL/min), it represented less than 50%. The gain in sensitivity observed in HILIC was found less significant with the recent LC-MS platforms used in this study than for old-generation instruments. Indeed, the improved ESI sources equipping the recent mass analyzers allow for enhanced evaporation efficiency, mainly for RPLC mobile phases containing high proportion of water and this even at high flow rates.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Eau, suitable for HPLC
Sigma-Aldrich
Hydroxyde d′ammonium solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Eau, Nuclease-Free Water, for Molecular Biology
Sigma-Aldrich
Eau, sterile-filtered, BioReagent, suitable for cell culture
Sigma-Aldrich
Eau, HPLC Plus
Sigma-Aldrich
Hydroxyde d′ammonium solution, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
Eau, Deionized
Sigma-Aldrich
Hydroxyde d′ammonium solution, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
Eau, for embryo transfer, sterile-filtered, BioXtra, suitable for mouse embryo cell culture
Sigma-Aldrich
Eau, for molecular biology, sterile filtered
Sigma-Aldrich
Hydroxyde d′ammonium solution, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis
Sigma-Aldrich
Eau, BioPerformance Certified
Sigma-Aldrich
Eau, ACS reagent
Sigma-Aldrich
Hydroxyde d′ammonium solution, puriss., meets analytical specification of Ph. Eur., 25-30% NH3 basis
Sigma-Aldrich
Hydroxyde d′ammonium solution, puriss. p.a. plus, ≥25% NH3 in H2O
Sigma-Aldrich
Eau, for cell biology, sterile ultrafiltered
Supelco
Eau, suitable for ion chromatography
Sigma-Aldrich
Salbutamol
Sigma-Aldrich
Reserpine
Sigma-Aldrich
Eau, PCR Reagent
Sigma-Aldrich
(1S,2S)-(+)-Pseudoephedrine, 98%
Sigma-Aldrich
Water, deuterium-depleted, ≤1 ppm (Deuterium oxide)
Sigma-Aldrich
Terfenadine
Sigma-Aldrich
Hydroxyde d′ammonium solution, BioUltra, ~1 M NH3 in H2O (T)
Supelco
Eau, for TOC analysis
Sigma-Aldrich
Eau, endotoxin, free
Sigma-Aldrich
Pindolol, ≥98% (TLC), powder
Supelco
Eau, ACS reagent, for ultratrace analysis
Eau, UKAS ISO/IEC17025 and ISO Guide 34 certified, density: 0.9982 g/mL at 20 °C, density: 0.9970 g/mL at 25 °C
Sigma-Aldrich
Tetracaine, ≥98% (TLC)