Pular para o conteúdo
Merck
Todas as fotos(1)

Key Documents

LNEHBA1C401

HbA1c in lyophilized hemolysates

LNE Certified Reference Material, commutable, JCTLM listed

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41116107
NACRES:
NA.24

forma

liquid

qualidade

commutable, JCTLM listed

prazo de validade

limited shelf life, expiry date on the label

composição

lyophilized human blood hemolysates, 100%

IVD

not for in vitro diagnostic use

temperatura de armazenamento

2-8°C

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

LNE CRM HbA1c 401 is a higher-order certified reference material produced by the French metrological institute LNE in compliance with ISO 17034 requirements. This Certified Reference Material LNE CRM HbA1c 401 corresponds to lyophilized human blood hemolysates and is intended for use as quality control materials for the verification of the accuracy of the reference method and routine methods used in clinical laboratories for the quantification of HbA1c in hemolysate or whole blood. Sample commutability was assessed through an extensive study involving seventeen of the most used method for the quantification of HbA1c in clinical laboratory using the difference in bias approach described in the IFCC recommendations on commutability assessment. Commutability results are reported in the certificate of analysis.

Cert_ LNE CRM HbA1c 401

Aplicação

The LNE CRM HbA1c 401 is a reference material designed for use as quality control material. It is intended for evaluating the measurement bias or uncertainty of existing or new measurement procedures for determining HbA1c in hemolysate or whole blood.

Características e benefícios

  • A reliable and consistent reference material for HbA1c measurement in clinical diagnostic assays. 
  • Certified for their HbA1c concentration using the IFCC reference method through LC/MS. 
  • Derived from real patient samples. 
  • This CRM is pooled, tested, and certified by the LNE, which includes extensive commutability studies. 
  • Commutability is assessed for the main routine assays. 
  • Target values are certified using higher-order reference methods that are calibrated using primary standards of certified purity or certified reference materials, which allows the establishment of metrological traceability of results to the SI units. 
  • The accuracy of the reference methods used to certify target values is verified using certified matrix reference materials. 
  • Recognized by the Joint Committee for Traceability in Laboratory Medicine (JCTLM) as higher order standards. 

Outras notas

  • Details on storage, safety, usage, and operating instructions are provided in the comprehensive Certificate of Analysis. 
  • This clinical matrix CRM is for research and clinical testing applications. 

Código de classe de armazenamento

10 - Combustible liquids

Classe de risco de água (WGK)

WGK 1

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica