Pular para o conteúdo
Merck
Todas as fotos(1)

Key Documents

29799-U

Supelco

SLB®-ILPAH Capillary GC Column

L × I.D. 20 m × 0.18 mm, df 0.05 μm

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41115710
NACRES:
SB.54

Materiais

fused silica

Nível de qualidade

Parâmetros

≤25-300 °C temperature (isothermal or programmed)

Valor beta

900

df

0.05 μm

técnica(s)

gas chromatography (GC): suitable

C × D.I.

20 m × 0.18 mm

Grupo ativo da matriz

Non-bonded; 1,12-di(tripropylphosphonium)dodecane bis(trifluoromethanesulfonyl)imide phase

aplicação(ões)

food and beverages

tipo de coluna

capillary polar

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Application: This special purpose and specially tested capillary GC column is designed for the analysis of polycyclic aromatic hydrocarbons (PAHs). It incorporates an ionic liquid stationary phase. Each column is individually tested to ensure resolution of several key sets (phenanthrene/anthracene, benzo[a]anthracene/chrysene/triphenylene, and benzo [b]fluoranthene/benzo[k]fluoranthene/benzo[j]fluoranthene).
USP Code: None
Phase: Non-bonded; 1,12-Di(tripropylphosphonium)dodecane bis(trifluoromethanesulfonyl)imide
Temp. Limits: Subambient to 300 °C (isothermal or programmed)

Aplicação

Retention behavior of alkyl-substituted polycyclic aromatic sulfur heterocycle isomers in gas chromatography on stationary phases of different selectivity
This study investigates the retention behavior of polycyclic aromatic sulfur heterocycles (PASHs) using gas chromatography with different stationary phases, including ionic liquids (ILs). The IL phase demonstrated unique selectivity and correlation with PASH geometry. (Wilson, Lee, et al, 2017)

https://doi.org/10.1016/j.chroma.2017.01.026

Retention behavior of isomeric polycyclic aromatic sulfur heterocycles in gas chromatography on stationary phases of different selectivity
The research evaluates the gas chromatographic retention indices of alkyl-substituted PASHs using various stationary phases, including ionic liquids. Results indicate that ILs offer distinct selectivity and thermal stability, enhancing the separation of complex mixtures.
(Wilson, Lee, et al, 2017)
https://doi.org/10.1016/j.chroma.2017.01.024

Ultra-high thermal stability perarylated ionic liquids as gas chromatographic stationary phases for the selective separation of polyaromatic hydrocarbons and polychlorinated biphenyls
This article explores the use of perarylated ionic liquids as stationary phases in gas chromatography for separating polycyclic aromatic hydrocarbons and polychlorinated biphenyls. The ILs exhibit high thermal stability and unique selectivity, improving the resolution of challenging analytes.
(Anderson & Davis, 2019)
https://doi.org/10.1016/j.chroma.2

Informações legais

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany

Código de classe de armazenamento

11 - Combustible Solids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Artigos

SLB®-ILPAH is a special purpose column based on an ionic liquid stationary phase providing unique selectivity and efficient column dimensions allowing exceptional resolution of PAHs

Protocolos

ionic liquids can successfully be used as viable GC stationary phases. These consist of two or more organic cations joined by a linkage, and associated with... improved inertness for polar analytes was the inspiration for the development of SLB™-IL (i-series) ionic liquid capillary GC columns. They solve a dilemma.

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica