29735-U
SLB®-1ms Capillary GC Column
L × I.D. 15 m × 0.32 mm, df 0.25 μm
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Materiais
fused silica
Nível de qualidade
Agency
meets requirements for USP G1, G2 and G9
Parâmetros
-60-340 °C temperature (isothermal)
-60-360 °C temperature (programmed)
Valor beta
320
df
0.25 μm
técnica(s)
GC/MS: suitable
gas chromatography (GC): suitable
C × D.I.
15 m × 0.32 mm
Grupo ativo da matriz
Bonded and crosslinked; poly(dimethyl siloxane) phase
aplicação(ões)
petroleum
tipo de coluna
capillary non-polar
Procurando produtos similares? Visita Guia de comparação de produtos
Descrição geral
Application: The non-polar dimethyl phase provides a boiling point elution order. The low bleed characteristics, inertness, and durable nature make it the column of choice for many petrochemical appplications, or anywhere a low bleed non-polar column is required.
USP Code: This column meets USP G1, G2, and G9 requirements.
Phase:
USP Code: This column meets USP G1, G2, and G9 requirements.
Phase:
- Bonded and crosslinked
- Poly(dimethyl siloxane)
- -60 °C to 340 °C (isothermal) or 360 °C (programmed)
Informações legais
SLB is a registered trademark of Merck KGaA, Darmstadt, Germany
Escolha uma das versões mais recentes:
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Langmuir : the ACS journal of surfaces and colloids, 27(16), 9662-9665 (2011-07-19)
Hierarchic structure and anomalous diffusion on submicrometer scale were introduced into an artificial cell membrane, and the spatiotemporal dependence of lipid diffusion was visualized on nanostructured oxide surfaces. We observed the lipid diffusion in supported lipid bilayers (SLBs) on step-and-terrace
Lipids, 51(12), 1427-1433 (2016-11-18)
Human liver cells (HepG2) were cultured with individual trans (t) 18:1 including t6-, t12-, t13-, t14-, t15- and t16-18:1, and retention times of their Δ-9 desaturation products were determined using 100-m biscyanopropyl-polysiloxane and SLB-IL111 columns. Corresponding peaks were found in
Journal of colloid and interface science, 297(1), 303-311 (2005-11-23)
We present new NMR techniques to characterize food products that are based on the measurement of two-dimensional diffusion-T2 relaxation and T1-T2 relaxation distribution functions. These measurements can be performed in magnets of modest strength and low homogeneity and do not
Single giant vesicle rupture events reveal multiple mechanisms of glass-supported bilayer formation.
Biophysical journal, 92(6), 1988-1999 (2006-12-26)
The formation of supported lipid bilayers (SLBs) on glass from giant unilamellar vesicles (GUVs) was studied using fluorescence microscopy. We show that GUV rupture occurs by at least four mechanisms, including 1), spontaneous rupture of isolated GUVs yielding almost heart-shaped
Se pu = Chinese journal of chromatography, 32(8), 886-889 (2014-12-02)
An analytical method was established for the determination of propargite, tebuconazole and bromopropylate in Taiwan green jujubes (Zizyphus mauritiana Lam) by gas chromatography-tandem mass spectrometry (GC-MS/MS). The sample was extracted with acetonitrile from the Taiwan green jujubes after treated with
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica