24257
SP®-2331 Capillary GC Column
L × I.D. 30 m × 0.25 mm, df 0.20 μm
Sinônimo(s):
SP-2331, 30M .25MM .20UM
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Materiais
fused silica
Nível de qualidade
Agency
suitable for EPA 1613
Parâmetros
≤25-275 °C temperature (isothermal or programmed)
Valor beta
313
df
0.20 μm
técnica(s)
gas chromatography (GC): suitable
C × D.I.
30 m × 0.25 mm
aplicação(ões)
agriculture
environmental
food and beverages
tipo de coluna
capillary highly polar
Procurando produtos similares? Visita Guia de comparação de produtos
Descrição geral
Application: A highly polar cyanosiloxane column specially tested for analyses of dioxins, specifically tetrachlorodibenzodioxin (TCDD) isomers. Because the phase is stabilized, it has a maximum temperature slightly higher than non-bonded cyanosiloxane columns.
USP Code: None
Phase:
USP Code: None
Phase:
- Stabilized
- Proprietary
- Subambient to 275 °C (isothermal or programmed)
Aplicação
SP® 2331 capillary column may be used in in high-resolution gas chromatography coupled with mass selective detection (HRGC-MSD) for selective separation of 2, 3, 7, 8-tetrachlorodibenzofuran. It was also used in HRGC-MSD for the analysis of chlorinated biphenyls, chlorinated dibenzodioxins, and chlorinated dibenzofurans. It was also used in the gas chromatographic separations of pyrethroid insecticides allethrin and cypermethrin in various achiral and chiral stationary phases.
Outras notas
We offer a variety of chromatography accessories including analytical syringes
Informações legais
SP is a registered trademark of Sigma-Aldrich Co. LLC
Aplicação
Nº do produto
Descrição
Preços
Escolha uma das versões mais recentes:
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Diastereoselective and enantioselective chromatography of the pyrethroid insecticides allethrin and cypermethrin.
Chromatographia, 33 (3-4), 103-112 (1992)
Selective separation of 2, 3, 7, 8-tetrachlorodibenzofuran by high-resolution gas chromatography and by alumina column liquid chromatography.
Analytical Chemistry, 59 (20), 2536-2538 (1987)
Agriculture and Soil Pollution.
Nature, 41-44 (2005)
The determination of chlorinated biphenyls, chlorinated dibenzodioxins, and chlorinated dibenzofurans by GC-MS.
Journal of High Resolution Chromatography, 15 (4), 260-270 (1992)
Journal of chromatography. A, 1139(2), 285-300 (2006-12-13)
The applicability of 13 different GC columns (Agilent HP-5MS, Restek Rtx-5MS, Rtx-Dioxin2, Supelco Equity 5, SP-2331, Varian VF-5MS, CP-Sil 8 CB LowBleed/MS, J&W Scientific DB-5, DB-225, DB-XLB, DB-5MS, Phenomenex ZB-5MS, and ZB-5UMS) for US Environmental Protection Agency (EPA) methods 1613b
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica