24152
Omegawax Capillary GC Column
L × I.D. 30 m × 0.32 mm, df 0.25 μm
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Materiais
fused silica
Nível de qualidade
Agency
meets requirements for USP G16
embalagem
pkg of 1 ea
Parâmetros
50-280 °C temperature (isothermal or programmed)
Valor beta
320
df
0.25 μm
técnica(s)
gas chromatography (GC): suitable
C × D.I.
30 m × 0.32 mm
Grupo ativo da matriz
Bonded; poly(ethylene glycol) phase
aplicação(ões)
agriculture
biofuels
clinical
food and beverages
tipo de coluna
capillary polar
Procurando produtos similares? Visita Guia de comparação de produtos
Categorias relacionadas
Descrição geral
Application: This column allows highly reproducible analyses of fatty acid methyl esters (FAMEs), specifically the omega 3 and omega 6 fatty acids. It is tested to ensure reproducible FAME equivalent chain length (ECL) values and resolution of key components.
USP Code: This column meets USP G16 requirements.
Phase:
USP Code: This column meets USP G16 requirements.
Phase:
- Bonded
- Poly(ethylene glycol)
- 50 °C to 280 °C (isothermal or programmed)
Outras notas
We offer a variety of chromatography accessories including analytical syringes
Informações legais
Escolha uma das versões mais recentes:
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Os clientes também visualizaram
Lipids, 35(2), 131-135 (2000-04-11)
This paper deals with the reanalysis of serum lipids from previous studies in which deuterated fatty acids were administered to a single person. Samples were reanalyzed to determine if the deuterated fatty acids were converted to deuterium-labeled conjugated linoleic acid
Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography.
Analytical Chemistry, 69 (16), 3140-3147 (1997)
Comparison of two gas-liquid chromatograph columns for the analysis of fatty acids in ruminant meat.
Journal of chromatography. A, 1216(26), 5130-5139 (2009-05-19)
Two gas-liquid chromatograph capillary columns for the analysis of fatty acids (FA) in ruminant fat are compared. Those columns are the CP-Sil 88 of 100 m long with a highly polar stationary phase and the Omegawax 250 of 30 m
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 770(1-2), 91-99 (2002-05-16)
Four capillary columns (A: CP-WAX 52 CB 25 m x 0.25 mm; B: CP WAX 52 CB 30 m x 0.25 mm; C: CP-WAX 58 CB 25 m x 0.25 mm, Chrompack; D: OMEGAWAX 320 30 m x 0.32 mm
Analytical chemistry, 71(19), 4237-4244 (1999-10-12)
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) was evaluated for the determination of beta-blockers in urine and serum samples. In-tube SPME is an extraction technique for organic compounds in aqueous samples
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica