C1413
Complement C7 deficient serum human
for complement assays
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Aplicação
Complement C7 deficiencies in humans are rare, but often associated with recurrent infections by Neisseria spp. (such as meningitis). C7 deficiencies in patients with meningococcal meningitis have shown a mutation which results in an 11 bp deletion in exon 6 resulting in a premature stop codon. Additionally, research has suggested that screening of patients with systemic neisserial infection by CH50 or the APH-50 assay can reveal a C7 deficiency.
forma física
Supplied as a solution in PBS, pH 7.4
Nota de análise
C7 is depleted by immunoadsorption as judged by a highly sensitive hemolytic assay.
Exoneração de responsabilidade
RESEARCH USE ONLY. This product is regulated in France when intended to be used for scientific purposes, including for import and export activities (Article L 1211-1 paragraph 2 of the Public Health Code). The purchaser (i.e. enduser) is required to obtain an import authorization from the France Ministry of Research referred in the Article L1245-5-1 II. of Public Health Code. By ordering this product, you are confirming that you have obtained the proper import authorization.
Código de classe de armazenamento
10 - Combustible liquids
Classe de risco de água (WGK)
WGK 3
Ponto de fulgor (°F)
Not applicable
Ponto de fulgor (°C)
Not applicable
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Immunology, 118(2), 257-260 (2006-06-15)
Different genetic mutations have been described in complement components resulting in total or subtotal deficiency states. In this work we report the genetic basis of C7 deficiency in a previously reported Spanish patient exhibiting a combined total deficiency of C7
Journal of immunology (Baltimore, Md. : 1950), 122(5), 2103-2111 (1979-05-01)
C1q, a subcomponent of the first component of complement, has been isolated from human serum in fully hemolytically active form by affinity column chromatography and gel filtration with Bio-Gel A-5M. The affinity column was prepared by covalent coupling of purified
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica