Pular para o conteúdo
Merck
Todas as fotos(2)

Documentos Principais

71009-576BC

Millipore

GDS Listeria spp. Tq

suitable for RT-PCR, for Listeria spp.

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41106302
NACRES:
NA.85

Agency

according to Immunomagnetic Separation (IMS)
meets requirements for AOAC® (PTM)
meets requirements for Health Canada
meets requirements for MicroVal

Nível de qualidade

linha de produto

Assurance GDS®

prazo de validade

6-12 mo.

Características

0.1 mL tubes

embalagem

pkg of 576 tests

técnica(s)

RT-PCR: suitable

aplicação(ões)

food and beverages
pathogen testing

compatibilidade

configured for BioControl Systems GDS Rotor-Gene
configured for BioControl Systems GDS

temperatura de armazenamento

2-8°C

adequação

Listeria spp.

Descrição geral

Assurance® GDS, genetic detection system, for Listeria spp. Tq is an automated nucleic acid amplification system for the detection of Listeria in food and environmental samples. The proprietary PickPen® IMS-based sample preparation procedure quickly and effectively captures Listeria spp., separating the pathogen from inhibitory background materials ensuring valid PCR reactions for all sample types, including challenging food and environmental samples. Assurance® GDS PCR technology provides two additional levels of specificity through the use of both highly specific primers and probes to ensure accurate detection of Listeria spp.

Aplicação

GDS, Genetic Detection System, for Listeria spp. Tq is an automated nucleic acid amplification system for the detection of Listeria species in foods, ingredients, and environmental samples.

Características e benefícios

  • Results in 24 hours for environmental samples and 32 hours for product samples
  • Single-step enrichment reduces handling time
  • Features innovative PickPen® immunomagnetic separation (IMS) for additional specificity and faster time to results
  • Simplified sample prep does not require heating blocks or preparation of reagents
  • Proprietary Rotor-Gene® Q cycler is a rotory-based cycler that ensures uniform heating and cooling of all samples

Componentes

Each 576 test kit includes:
  • Listeria spp. Amplification Tubes Tq (0.1 mL)
  • Listeria Concentration Reagent
  • Listeria Resuspension Buffer Tq
  • Wash Solution

NOTE: The 100 kit includes standard 0.2 mL amp tubes whereas the 576 kit includes smaller 0.1 mL amp tubes. The 576 kit requires additional equipment tools to process per the kit Directions for Use.

Compatibilidade

BioControl® GDS

Método de teste

PCR, Immunomagnetic Separation (IMS)

Informações legais

AOAC is a registered trademark of AOAC International
Assurance is a registered trademark of Merck KGaA, Darmstadt, Germany
Assurance GDS is a registered trademark of BioControl Systems, Inc.
BioControl is a registered trademark of BioControl Systems, Inc.
PICKPEN is a registered trademark of Merck KGaA, Darmstadt, Germany
Rotor-Gene is a registered trademark of Qiagen GmbH

Código de classe de armazenamento

10 - Combustible liquids


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Se precisar de ajuda, entre em contato Atendimento ao cliente

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica