About This Item

Fórmula linear:
C6H5CH3
Número CAS:
Peso molecular:
92.14
Beilstein:
635760
Número MDL:
Código UNSPSC:
12352002
ID de substância PubChem:

grau

SAJ first grade

densidade de vapor

3.2 (vs air)

pressão de vapor

22 mmHg ( 20 °C)
26 mmHg ( 25 °C)

Ensaio

≥99.0%

Formulário

liquid

temperatura de autoignição

997 °F

Lim. expl.

7 %

disponibilidade

available only in Japan

índice de refração

n/D 1.496 (lit.)

p.e.

110-111 °C (lit.)

pf

-93 °C (lit.)

densidade

0.865 g/mL at 25 °C (lit.)

cadeia de caracteres SMILES

Cc1ccccc1

InChI

1S/C7H8/c1-7-5-3-2-4-6-7/h2-6H,1H3

chave InChI

YXFVVABEGXRONW-UHFFFAOYSA-N

Procurando produtos similares? Visita Guia de comparação de produtos

Palavra indicadora

Danger

Classificações de perigo

Aquatic Chronic 3 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

Órgãos-alvo

Central nervous system

Código de classe de armazenamento

3 - Flammable liquids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

39.2 °F

Ponto de fulgor (°C)

4 °C


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Ting Lei et al.
Small (Weinheim an der Bergstrasse, Germany), 11(24), 2946-2954 (2015-02-26)
Low-bandgap diketopyrrolopyrrole (DPP)-based polymers are used for the selective dispersion of semiconducting single-walled carbon nanotubes (s-SWCNTs). Through rational molecular design to tune the polymer-SWCNT interactions, highly selective dispersions of s-SWCNTs with diameters mainly around 1.5 nm are achieved. The influences
Liang Guo et al.
Journal of chromatography. A, 1286, 9-15 (2013-03-19)
For the first time, a novel one-step sample preparation method that combines microwave assisted extraction and solvent bar microextraction (MAE-SBME) with analysis by gas chromatography-mass spectrometry (GC-MS), was developed for the fast and efficient determination of polycyclic aromatic hydrocarbons (PAHs)
Christopher M Filley et al.
Journal of neuropathology and experimental neurology, 63(1), 1-12 (2004-01-30)
In recent decades the organic solvent toluene (methylbenzene) has emerged as one of the best-studied neurotoxins. Long-term and intense exposure to toluene vapors in humans who abuse spray paint and related substances has led to the recognition that toluene has
Murat Yücel et al.
Neuroscience and biobehavioral reviews, 32(5), 910-926 (2008-05-06)
Organic solvent abuse is associated with increased risk for serious medical, neurological, and neuropsychological impairments. While animal research suggests that exposure to organic solvents (especially toluene) may be neurotoxic, much less is known about the consequences of long-term exposure in
Yoko Yamakoshi et al.
Faraday discussions, 173, 287-296 (2014-12-04)
The photoinduced reactive oxygen species (ROS) generation from several water-soluble fullerenes was examined. Macromolecular or small molecular water-soluble fullerene complexes/derivatives were prepared and their (1)O(2) and O(2)˙(-) generation abilities were evaluated by ESR spin-trapping methods. As a result, efficient (1)O(2)

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica