KVEPS3TTT1
Millipore Express® SHR, Opticap® XLT Capsule
Opticap® XLT 30, sterile, inlet connection diam. 1.5 in., cartridge nominal length 30 in. (75 cm)
Sinônimo(s):
Opticap Sterile XLT 30 Millipore Express SHR single layer 0.1μm 1-1/2 in. TC/TC without gauge port
About This Item
Produtos recomendados
Materiais
polyester support
polyethersulfone
polypropylene
polypropylene housing
polypropylene vent cap
silicone seal
Nível de qualidade
conformidade reg.
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
esterilidade
irradiated
sterile
linha de produto
Opticap® XLT 30
Características
hydrophilic
fabricante/nome comercial
Millipore Express®
Parâmetros
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
técnica(s)
sterile filtration: suitable
Comprimento
87.2 cm (34.3 in.)
comprimento nominal do cartucho
30 in. (75 cm)
Diâmetro
10.7 cm (4.2 in.)
área de filtração
2.06 m2
diâm. conexão de entrada
1.5 in.
L entrada para a saída
15.2 cm (6.0 in.)
diam. conexão de saída
1.5 in.
Impurezas
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
matriz
Millipore Express® SHR
tamanho de poro
0.1 μm
ponto de bolha
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C
conector
1/4 in. drain/vent hose barb (with double O-ring Seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
Categorias relacionadas
Descrição geral
Embalagem
Outras notas
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Nota de preparo
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Nota de análise
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 33 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Informações legais
Não está encontrando o produto certo?
Experimente o nosso Ferramenta de seleção de produtos.
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica