KHGEG3TTT1H
Millipore Express® SHC High Area, Opticap® XLT Capsule
cartridge nominal length 30 in. (75 cm), Opticap® XLT 30
Sinônimo(s):
Gamma Compatible High Area Opticap® XLT 30 Millipore Express® SHC 0.5 µm/0.2 µm 1-1/2 in. TC
About This Item
Produtos recomendados
Materiais
polyester support
polyethersulfone
polypropylene
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal
Nível de qualidade
conformidade reg.
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
esterilidade
non-sterile
Compatibilidade de esterilização
gamma compatible
linha de produto
Opticap® XLT 30
Características
hydrophilic
fabricante/nome comercial
Millipore Express®
Parâmetros
≤169.2 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psi) at 80 °C (Forward)
2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psi) at 25 °C (Forward)
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
80 psig max. inlet pressure
técnica(s)
sterile filtration: suitable
Comprimento
87.1 cm (34.3 in.)
Largura
7.8 in.
comprimento nominal do cartucho
30 in. (75 cm)
Diâmetro
10.7 in. (4.2 cm)
área de filtração
3.0 m2
L entrada para a saída
15.2 cm (6.0 in.)
diam. conexão de saída
1.5 in.
Impurezas
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
matriz
Millipore Express® SHC High Area
pore size
0.5/0.2 μm pore size
ponto de bolha
≥4000 mbar (58 psig), air with water at 23 °C
conector
1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet sanitary flange
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
aplicação(ões)
sample preparation
Descrição geral
Embalagem
Outras notas
Nota de preparo
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Nota de análise
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 63 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Informações legais
Não está encontrando o produto certo?
Experimente o nosso Ferramenta de seleção de produtos.
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica