HMHEMAG-34K
MILLIPLEX® Human Metabolic Hormone Magnetic Bead Panel - Metabolism Multiplex Assay
The Human Metabolic Hormone Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 13 protein biomarkers in human serum, plasma and cell/tissue culture samples.
Sinônimo(s):
human metabolic hormone immunoassay panel, luminex human metabolic hormone multiplex assay, millipore human metabolism multiplex kit
About This Item
Produtos recomendados
reatividade de espécies
human
fabricante/nome comercial
Milliplex®
assay range
accuracy: 101%
(Glucagon)
accuracy: 102%
(Leptin)
accuracy: 103%
(GIP)
accuracy: 103%
(GLP-1 (Total))
accuracy: 105%
(Ghrelin (Active))
accuracy: 106%
(MCP-1)
accuracy: 97%
(TNFα)
accuracy: 99%
(C-Peptide)
sensitivity: 0.5 pg/mL
(MinDC+2SD; TNF?)
sensitivity: 1.1 pg/mL
(MinDC+2SD; GIP)
sensitivity: 13 pg/mL
(MinDC+2SD; IL-6)
sensitivity: 14 pg/mL
(MinDC+2SD; Ghrelin (Active))
sensitivity: 14 pg/mL
(MinDC+2SD; MCP-1)
sensitivity: 146 pg/mL
(MinDC+2SD; PYY)
sensitivity: 15 pg/mL
(MinDC+2SD; Amylin (Total))
sensitivity: 16 pg/mL
(MinDC+2SD; C-Peptide)
sensitivity: 16 pg/mL
(MinDC+2SD; Glucagon)
sensitivity: 160 pg/mL
(MinDC+2SD; Insulin)
sensitivity: 2.4 pg/mL
(MinDC+2SD; GLP-1 (Active))
sensitivity: 2.9 pg/mL
(MinDC+2SD; PP)
sensitivity: 28 pg/mL
(MinDC+2SD; Amylin (Active))
sensitivity: 64 pg/mL
(MinDC+2SD; Leptin)
sensitivity: 7.3 pg/mL
(MinDC+2SD; GLP-1 (Total))
standard curve range: 0.69-500 pg/mL
(TNFα)
standard curve range: 1.4-1,000 pg/mL
(GIP)
standard curve range: 13.7-10,000 pg/mL
(Amylin (Active))
standard curve range: 13.7-10,000 pg/mL
(Amylin (Total))
standard curve range: 13.7-10,000 pg/mL
(Ghrelin (Active))
standard curve range: 13.7-10,000 pg/mL
(Glucagon)
standard curve range: 13.7-10,000 pg/mL
(IL-6)
standard curve range: 13.7-10,000 pg/mL
(MCP-1)
standard curve range: 13.7-10,000 pg/mL
(PYY)
standard curve range: 137-100,000 pg/mL
(Insulin)
standard curve range: 137-100,000 pg/mL
(Leptin)
standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Active))
standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Total))
standard curve range: 2.7-2,000 pg/mL
(PP)
standard curve range: 27.4-20,000 pg/mL
(C-Peptide)
inter-assay cv: <15%
intra-assay cv: <10%
(C-Peptide)
inter-assay cv: <15%
intra-assay cv: <10%
(GIP)
inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Active))
inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Total))
inter-assay cv: <15%
intra-assay cv: <10%
(Ghrelin (Active))
inter-assay cv: <15%
intra-assay cv: <10%
(Glucagon)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <15%
intra-assay cv: <10%
(Insulin)
inter-assay cv: <15%
intra-assay cv: <10%
(Leptin)
inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1)
inter-assay cv: <15%
intra-assay cv: <10%
(PP)
inter-assay cv: <15%
intra-assay cv: <10%
(PYY)
inter-assay cv: <15%
intra-assay cv: <10%
(TNFα)
inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Active))
inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Total))
técnica(s)
multiplexing: suitable
método de detecção
fluorometric (Luminex xMAP)
Condições de expedição
wet ice
Descrição geral
The MILLIPLEX® Human Metabolic Hormone Panel is a 15 analyte, 13-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and cell/tissue culture samples: Amylin (Active) or Amylin (Total), C-Peptide, Ghrelin (Active), GIP, GLP-1 (Active) or GLP-1 (Total), Glucagon, IL-6, Insulin, Leptin, MCP-1, PP, PYY, TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
Aplicação
- Analytes: Amylin (Active), Amylin (Total), C-Peptide, Ghrelin (Active), GIP (Total), GLP-1 (Active), GLP-1 (Total), Glucagon, IL-6, Insulin, Leptin, MCP-1 (CCL2), Pancreatic Polypeptide (PP), PYY (Total), TNF-α
- NOTE: The following analytes cannot be assayed simultaneously: Amylin (Active) & Amylin (Total); GLP-1 (Active) & GLP-1 (Total).
- Recommended Sample Type: Human serum, plasma, and cell/tissue culture supernatants or lysates
- Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma; cell/tissue culture samples may be used undiluted or diluted with an appropriate control medium NOTE: The following analytes require the addition of protease inhibitors to serum or plasma samples (see sample collection and storage section in the protocol for details): GLP-1 (DPPIV inhibitor); Amylin (protease inhibitor cocktail); Glucagon (Aprotinin); Ghrelin (Active) (serine protease inhibitor).
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Metabolic Disorders
Características e benefícios
Ligação
Outras notas
Informações legais
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
Código de classe de armazenamento
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Conteúdo relacionado
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica