Pular para o conteúdo
Merck
Todas as fotos(1)

Key Documents

CBA024

Sigma-Aldrich

InnoZyme Myeloperoxidase Activity Kit

Sinônimo(s):

InnoZyme MPO Activity Kit

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41116133
NACRES:
NA.77

uso

sufficient for 96 tests

Nível de qualidade

reatividade de espécies

human

embalagem

pkg of 1 96-well plate(s)

fabricante/nome comercial

Calbiochem®

condição de armazenamento

OK to freeze
avoid repeated freeze/thaw cycles
protect from light

assay range

sensitivity: 330 pg/mL
standard curve range: 5-100 ng/mL

entrada

sample type serum
sample type cerebrospinal fluid (CSF)
sample type cell lysate

método de detecção

colorimetric

Condições de expedição

wet ice

temperatura de armazenamento

−20°C

Descrição geral

The InnoZyme Myeloperoxidase Activity Kit is a specific and sensitive assay designed to measure myeloperoxidase activity and to screen enzyme inhibitors. The assay uses a polyclonal antibody specific for human MPO immobilized on a 96-well plate to specifically capture the enzyme. Activity of captured myeloperoxidase is measured using a detection reagent that includes TMB and hydrogen peroxide. Following color development, the reaction is stopped with sulfuric acid and the absorbance of the oxidized TMB is detected at 450 nm.

Componentes

Anti-MPO Coated 96-Well Plate, MPO Standard, TMB, Hydrogen Peroxide, Assay Buffer, Sample Buffer, Stop Solution, Plate Sealers, and a user protocol.

Advertência

Toxicity: Multiple Toxicity Values, refer to MSDS (O)

Especificações

Assay Time: 2 h

Princípio

The Calbiochem InnoZyme Myeloperoxidase Activity Kit is designed to measure human myeloperoxidase activity in cell lysates and biological samples and to screen enzyme inhibitors.

Nota de preparo

All reagents necessary to perform the assay are supplied with the kit. Equilibrate all reagents to room temperature (15-25°C) just prior to use.Sample Buffer (1X): Dilute Sample Buffer 1:20 by adding 25 ml Sample Buffer to 475 ml dH2O. Myeloperoxidase Standard (1g/ml): Dilute the Myeloperoxidase Standard 1:100 by adding 5 l Myeloperoxidase Standard to 495 l chilled Sample Buffer (1X) obtain a concentration of 1 g/ml. Maintain the diluted Myeloperoxidase Standard (1 g/ml) on ice. Note: Following initial thaw the Myeloperoxidase Standard should be dispensed into aliquots and stored at -20°C. Avoid freeze/thaw cycles.<div class="Bio_doc_image">
Table 1: Myeloperoxidase Standard Dilutions
Prepare Myeloperoxidase Standard dilutions in the range of 5-100 ng/ml using the above guidelines.
</div>Hydrogen Peroxide (0.3%): Dilute the Hydrogen Peroxide (30%) 1:100 by adding 5 l Hydrogen Peroxide (30%) to 495 l chilled dH2O. Note: A total of 40 l is required to cover the entire Coated 96-Well Plate. If the entire plate is not to be used at one time, prepare fresh Hydrogen Peroxide (0.3%) each time the assay is performed. Following initial thaw the Hydrogen Peroxide should be dispensed into aliquots and stored at -20°C. Avoid freeze/thaw cycles.TMB Detection Reagent: Note: The desired amount of TMB Detection Reagent should be prepared fresh, just prior to use. To prepare TMB Detection Reagent, mix the following components:
  • 7.16 ml dH2O
  • 2.00 ml Assay Buffer
  • 0.80 ml TMB
  • 40 l H2O2(0.3%)

Vortex gently 3 X 3 sTo prepare TMB Detection Reagent for a variable number of strips, use the following guidelines: <div class="Bio_doc_image">Table 2: Preparation of TMB Detection Reagent
To prepare TMB Detection Reagent for a variable number of strips, use the above guidelines.
</div>
Dilute samples with Sample Buffer (1X) as needed. Note: If sample dilution is not required for sensitivity reasons, prepare the sample by adding 475 µl sample to 25 µl 20X Sample Buffer to ensure appropriate pH for the first incubation.

Armazenamento e estabilidade

Upon arrival, store the unopened kit at -20°C. All kit components, once opened, can be stored for up to 3 months under the following conditions:



Store at 4°C: TMB, Anti-MPO Coated 96-Well Plate, Assay Buffer, Stop Solution, and Sample Buffer

Store at -20°C: Myeloperoxidase Standard, and Hydrogen Peroxide



Note: Following initial use the Myeloperoxidase Standard and the Hydrogen Peroxide should be dispensed into aliquots and stored at -20°C. Avoid freeze/thaw cycles.

Nota de análise

Positive Control
Human myeloperoxidase

Outras notas

Due to the nature of the Hazardous Materials in this shipment, additional shipping charges may be applied to your order. Certain sizes may be exempt from the additional hazardous materials shipping charges. Please contact your local sales office for more information regarding these charges.
Weil, S.C., et al. 1988. Science 240, 790.
Winterbourn, C.C., et al. 2000. Curr. Opin. Hematol. 7, 53.
Brennan, M.L., et al. 2003. New Engl. J Med. 349, 1595.
Zheng, L., et al. 2004. J. Biol. Chem. in press
Vita, J.A., et al. 2004. Circulation, 110, 1134.

Informações legais

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogramas

CorrosionExclamation mark

Palavra indicadora

Danger

Frases de perigo

Classificações de perigo

Eye Dam. 1 - Met. Corr. 1 - Skin Irrit. 2 - Skin Sens. 1

Código de classe de armazenamento

8A - Combustible corrosive hazardous materials


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Alessandro Trentini et al.
Inflammation research : official journal of the European Histamine Research Society ... [et al.], 63(5), 325-328 (2014-01-25)
We investigated the effect of balanced (BS) and unbalanced (UBS) solutions in the absence or presence of hydroxyethyl starch (HES) on neutrophil functionality, evaluating the release of matrix metalloproteinase (MMP)-9, myeloperoxidase (MPO), and MMP-8. Neutrophils were isolated by gradient centrifugation