1.13726
HPTLC plates, Silica gel 60 RP-2 F₂₅₄s
pkg of 25 plates, plate L × W 10 cm × 10 cm, glass support
Sinônimo(s):
Reverse Phase Silica Gel 60 Plates
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Materiais
glass support
silica gel 60 matrix
Nível de qualidade
Características
binder Organic Polymer
fluorescent indicator
embalagem
pkg of 25 plates
técnica(s)
thin layer chromatography (TLC): suitable
espessura da camada
200 μm
placa C × L
10 cm × 10 cm
tamanho de partícula
5-6 μm
tamanho de poro
60 Å medium pore diameter
temperatura de armazenamento
2-30°C
Descrição geral
25 Glass plates 10 x 10 cm
RP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. Our RP-modified silica layers are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous solvent systems to separate extremely non-polar substances and analyze particular polar substances that can adapt to ion-pair chromatography. What’s more, RP-modified silica layers are less dependent on atmospheric humidity. Unlike unmodified silica, RP-phases do not exhibit catalytic activity. This makes them the plates of choice for unstable substance that tend to experience oxidative degradation.
Ligação
Replaces: 13726-5; 13726
Nota de análise
Specific surface area (according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testings:
A) Cholesterin test
hRf-values
- cholesterin, cholesterin test:
77 - 89
B) Steroid test
- methyltestosterone, steroid test: 57 - 77
- Reichstein S, steroid test: 66 - 86
- hydrocortisone, steroid test: 70 - 90
Typical value determined on an activated plate (120°C, 15 min)
Eluent a) aceton/ water (95/5 v/v)
Eluent b) acetonitrile/ water (70/30 v/v)
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testings:
A) Cholesterin test
hRf-values
- cholesterin, cholesterin test:
77 - 89
B) Steroid test
- methyltestosterone, steroid test: 57 - 77
- Reichstein S, steroid test: 66 - 86
- hydrocortisone, steroid test: 70 - 90
Typical value determined on an activated plate (120°C, 15 min)
Eluent a) aceton/ water (95/5 v/v)
Eluent b) acetonitrile/ water (70/30 v/v)
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica