266264
Chromium
powder, 99.5%, −100 mesh
Sinônimo(s):
Cd
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Nível de qualidade
Ensaio
99.5%
forma
powder
adequação da reação
core: chromium
reagent type: catalyst
resistividade
12.7 μΩ-cm, 20°C
tamanho de partícula
−100 mesh
pb
2672 °C (lit.)
pf
1857 °C (lit.)
densidade
7.14 g/mL at 25 °C (lit.)
cadeia de caracteres SMILES
[Cr]
InChI
1S/Cr
chave InChI
VYZAMTAEIAYCRO-UHFFFAOYSA-N
Procurando produtos similares? Visita Guia de comparação de produtos
Aplicação
Chromium powder can be used in the microwave assisted synthesis of a bis(toluene)chromium boron complex, [Cr(η-C6H5CH3)2]+ (BPh4)-. It can also be used in the solid-state synthesis of chromium sulfide.
Código de classe de armazenamento
11 - Combustible Solids
Classe de risco de água (WGK)
nwg
Ponto de fulgor (°F)
Not applicable
Ponto de fulgor (°C)
Not applicable
Equipamento de proteção individual
Eyeshields, Gloves, type N95 (US)
Escolha uma das versões mais recentes:
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Os clientes também visualizaram
Synthetic reactions using metal powders under microwave irradiation.
J. Chem. Soc., Dalton Trans., 21, 3967-3970 (2002)
Microwave-assisted solid-state reactions involving metal powders.
J. Chem. Soc., Dalton Trans., 12, 2073-2079 (1995)
Journal of toxicology and environmental health. Part A, 66(4), 393-409 (2003-01-30)
Chromium-based catalysts are used for the synthesis of polyethylene, but little is known about the hazard and biomonitoring possibilities of this type of chromium for workers who may be occupationally exposed to such compounds. Therefore, the bioavailability and toxicokinetics of
Journal of exposure analysis and environmental epidemiology, 10(2), 103-114 (2000-05-03)
The German Environmental Survey (GerES) is a large-scale population study which has repeatedly been carried out in Germany. GerES I was conducted in 1985/1986 followed by GerES IIa in 1990/1991 (West Germany) and GerES IIb in 1991/1992 (East Germany). GerES
The Journal of bone and joint surgery. American volume, 95(8), 678-685 (2013-04-19)
Determining the relationship between clinical factors and engineering analysis of retrieved hip implants can help our understanding of the mechanism of device failure. This is particularly important for metal-on-metal hip arthroplasties because the most common cause of failure is unexplained.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica