Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

1.02129

Supelco

Chromolith® RP-18 endcapped (monolithic) HPLC Columns

L × I.D. 100 mm x 4.6 mm HPLC Column

Synonyme(s) :

Colonne Chromolith® RP-18 Endcapped.

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41115709
Nomenclature NACRES :
SB.52

Nom du produit

Colonne d'HPLC Chromolith® Performance RP-18 Endcapped 100-4,6, L × I.D. 100 mm x 4.6 mm HPLC column

Matériaux

PEEK column

Niveau de qualité

Agence

suitable for USP L1

Gamme de produits

Chromolith®

Caractéristiques

endcapped

Conditionnement

1 ea of

Ampleur du marquage

18% Carbon loading

Paramètres

200 bar pressure
45 °C max. temp.

Technique(s)

HPLC: suitable
LC/MS: suitable
mass spectrometry (MS): suitable (High)

Colonne, L × D.I.

10 cm × 4.6 mm

Matrice

monolithic silica

Groupe de la matrice active

C18 bonding phase

Dimension de pores

13 nm mesoporosity
2 μm macroporosity

Plage de pH de fonctionnement

2-7.5

Technique de séparation

reversed phase

Température de stockage

no temp limit

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Chromolith® columns are made of monolithic silica with a characteristic bimodal pore structure.

Chromolith® Performance RP-18 endcapped HPLC columns have macropores with 2 μm diameter, giving a column efficiency exceeding 80,000 plates/meter. The mesopores are 13 nm (130 Å) and the surface modification is octadecylsilane with full end-capping. Chromolith® Performance RP-18 endcapped columns fall under the USP L1 Classification. The column efficiency is comparable to a 5 μm particle size fully porous particulate column.

Chromolith® Performance RP-18 endcapped columns are perfectly suitable for LC-MS applications.
The column dimension of 100 mm length and 4.6 mm I.D. is the best choice for separations of complex samples on any HPLC System.

The revolutionary, monolithic silica with its unique combination of macropores and mesopores enables:
  • Rapid separations at very low column back-pressure
  • High matrix tolerance, allowing time and cost savings with simplified workflows
  • Cost savings due to extended column lifetimes
  • Connection of columns, flow gradients and the use of mobile phases with higher viscosity


The recommended Guard-columns are:
Chromolith® RP-18 endcapped 5-4.6 guard cartridges (3 pieces) [1.51452] with the Chromolith® Guard Cartridge Holder 5 mm x 4.6 mm [1.52032] Or Chromolith® RP-18 endcapped 10-4.6 guard cartridges (3 pieces) [1.51451] with the Chromolith® Guard Cartridge Holder 10 mm x 4.6 mm [1.52033]

The Chromolith® column coupler can be used to significantly increase the separation efficiency of Chromolith® columns by coupling several columns in series (up to 100,000 plates/per column). [1.51467]

Need more efficiency?
Chromolith® HighResolution RP-18 endcapped 100-4.6 HPLC columns [1.52022] provide a column efficiency exceeding 140,000 plates/meter.

Learn more:
Brochure: Race through your Separations on Any System. Chromolith® Monolithic Silica HPLC Columns

All Supelco HPLC Columns, including monolithic Chromolith® columns, are fully compatible to all HPLC and UHPLC Instruments.
Supelco HPLC Products: The Best Choice for Any LC Instrument

Application


  • Salt pollution reduces turbidity, dissolved organic matter, and cyanobacteria in experimental vernal pool communities : l'étude porte sur les applications environnementales du chlorure de calcium, en mettant l'accent sur son rôle dans la gestion des écosystèmes touchés par la pollution saline, et en illustrant son impact sur la dépollution et la préservation de l'environnement. (Vigil and Schuler, 2024).



Remarque sur l'analyse

Apparence : conforme
Teneur en carbone : 17,0 - 18,6 %
Pression : ≤ 30 bar
Tests de stabilité : conforme
Performance (anthracène)
Plateaux théoriques (N/m) (anthracène) : ≥ 80 000
Facteur de capacité (anthracène) : 3,9 - 4,6
Traînées de pics (USP) : 0,90 - 1,60 %
Sélectivité
facteur de séparation (anthracène/progestérone) : 1,95 - 2,35

Informations légales

Chromolith is a registered trademark of Merck KGaA, Darmstadt, Germany

Produit(s) apparenté(s)

Code de la classe de stockage

10-13 - German Storage Class 10 to 13


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Articles

Chromolith® HPLC and UHPLC columns are made from monolithic silica with a bimodal pore structure using sol-gel technology.

Monolithic silica HPLC columns enable high-throughput analysis at low back pressure without loss of separation efficiency or peak capacity.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique