T-111
Tetrahydrocannabivarinic acid (THCVA) solution
1.0 mg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®
About This Item
Produits recommandés
Qualité
certified reference material
Niveau de qualité
Forme
liquid
Caractéristiques
Snap-N-Spike®/Snap-N-Shoot®
Conditionnement
ampule of 1 mL
Fabricant/nom de marque
Cerilliant®
Concentration
1.0 mg/mL in acetonitrile
Technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
Application(s)
cannabis testing
cannabis testing
Format
single component solution
Conditions d'expédition
dry ice
Température de stockage
−70°C
InChI
1S/C20H26O4/c1-5-6-12-10-15-17(18(21)16(12)19(22)23)13-9-11(2)7-8-14(13)20(3,4)24-15/h9-10,13-14,21H,5-8H2,1-4H3,(H,22,23)
Clé InChI
IQSYWEWTWDEVNO-UHFFFAOYSA-N
Description générale
Tetrahydrocannabivarinic acid is the acidic precursor of the phytocannabinoid tetrahydrocannabivarin (THCV).
Application
- Determination of 18 cannabinoids and their metabolites in 55 forensic serum samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
- Screening and measuring 16 cannabinoids in cannabis plant materials, plant extracts, edible cannabis oils, and cannabis-based cosmetic products by 1H qNMR method and a novel 2D-COSY qNMR method
- Development and validation of liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying 17 cannabinoids in cannabis and hemp samples
- High-performance liquid chromatography-diode array detector (HPLC-DAD) method-based determination of 16 cannabinoids in hemp concentrates
- Base-line separation and quantification of 18 cannabinoids by liquid chromatography-diode array detector (LC-DAD) method
Caractéristiques et avantages
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Informations légales
Produit(s) apparenté(s)
Mention d'avertissement
Danger
Mentions de danger
Classification des risques
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 2
Point d'éclair (°F)
35.6 °F - closed cup
Point d'éclair (°C)
2.0 °C - closed cup
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Protocoles
Tetrahydrocannabinolic acid A solution, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material; Cannabichromenic Acid (CBCA) solution, 1.0 mg/mL in acetonitrile, certified reference material, ampule of 1 mL
HPLC separation of 17 important cannabinoids including CBD, delta 9 THC and THCA. Read the application note
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique