Direkt zum Inhalt
Merck

Flüchtige Fraktion von Limoncello

Flüchtige Fraktion von Limoncello application for SPME, suitable for GC

Materialien

Analytische Säule

Produkt-Nr.
Beschreibung
Preisangaben

SLB®-5ms GC-Kapillarsäule

L × I.D. 30 m × 0.25 mm, df 0.25 μm

SPME-Faser

Produkt-Nr.
Beschreibung
Preisangaben

SPME-Faseranordnung Polydimethylsiloxan (PDMS)

df 100 μm(PDMS, needle size 24 ga, for use with manual holder

Standard

Produkt-Nr.
Beschreibung
Preisangaben

Decanal

≥98% (GC), liquid

3,7-Dimethyl-2,6-octadienylacetat

mixture of isomers, >97.0% (sum of isomers, GC)

(R)-(+)-Limone

analytical standard

p-Cymol

analytical standard

α-Terpinen

≥95.0% (GC)

γ-Terpinen

analytical standard

Nerylacetat

analytical standard

(+)-α-Pinen

analytical standard

Myrcen

analytical standard

Geraniol

analytical standard

Nonyl acetate

≥97%, FCC

Valencen

natural, ≥65%

Terpinolen

≥95%, FG

Camphen

analytical standard

Nonanal

analytical standard

Linalool

analytical standard

Citral

analytical standard

(−)-α-Bisabolol

analytical standard

Octyl-Acetat

analytical standard

α-Terpineol

analytical standard

Octanal

analytical standard

α-Phellandren

natural, ≥85%, FG

Citronellylacetat

analytical standard

Undecanal

analytical standard

α-Humulen

analytical standard

Ähnliches Produkt

Produkt-Nr.
Beschreibung
Preisangaben

SPME-Faserhalter

for use with manual sampling

SPME-Faserhalter

for use with CTC CombiPAL and Gerstel MPS2

CONDITIONS

sample/matrix

Limoncello diluted 1:100 in water, then 5 mL of this solution transferred to a 10 mL crimped vial spiked with 100 μL of a 100 ppm solution of nonane (internal standard)

SPME fiber

100 μm polydimethylsiloxane (57300-U)

extraction

headspace, with a pre-equilibration period of 10 min. at 40 °C, and then a fiber exposure of 30 min. at 40 °C, agitated in an alternate clockwise-anticlockwise rotation mode at 500 ppm

desorption process

250 °C for 5 min

column

SLB-5ms, 30 m x 0.25 mm I.D., 0.25 μm (28471-U)

oven

40 °C, 3 °C/min to 250 °C (2 min)

inj. temp.

250 °C

detector

FID, 260 °C (sampling rate 80 ms)

carrier gas

helium, 35.0 cm/sec

injection

splitless

liner

0.75 mm I.D. SPME (2633901)

sample

Limoncello liquor

Beschreibung

Hinweis zur Analyse

In this application, SPME was used for the analysis of volatiles in limoncello using a headspace method. SPME is ideal for the analysis of aroma volatiles in flavored beverages such as liquors. A 100 μm PDMS fiber was inserted into the headspace of the limoncello sample for 30 minutes at 40 °C followed by GC analysis using FID detection. The SLB-5ms GC columns provide consistently low-bleed, inert, efficient, and durable separations.

Rechtliche Hinweise

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany