Direkt zum Inhalt
Merck

WHAUN203NPEPP

Whatman® Mini-UniPrep® spritzenlose Filter

PP, 0.2 μm, 100/pk

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
40161807
NACRES:
NB.24

Materialien

PTFE septa (PTFE coated silicone rubber)
polypropylene housing
polypropylene membrane

Sterilität

non-sterile

Verwendung

general filtration media/solvent based samples

Leistungsmerkmale

cap (Septa)
graduations: no
(equivalent in size to 12 x 32 mm vials)
nominal force to compress: approximately 18 lb / 8.2 kg

Verpackung

pkg of 100 ea

Hersteller/Markenname

Whatman UN203NPEPP

Filterkapazität

400 μL

Porengröße

0.2 μm

Eignung

suitable for (routine HPLC/UHPLC analysis, protein precipitation, solubility testing; sample filteration)

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Verwandte Kategorien

Allgemeine Beschreibung

Mini-UniPrep is a preassembled filtration device consisting of a 0.4 mL capacity chamber and a plunger. The plunger contains a filtration membrane at one end and a preattached cap/septum at the other. The plunger is pressed through the sample in the outer chamber and positive pressure forces the filtrate into the reservoir of the plunger.

Air escapes through the vent hole until the locking ring is engaged providing an air-tight seal. Within seconds the Mini-Uniprep can be placed into any able to contain 2 mL vials for injection into your instrument.

The Whatman Mini-UniPrep Syringeless Filters provide a faster and easier way to remove particulates from samples being prepared for High Performance Liquid Chromatography (HPLC)/ Ultra High Performance Liquid Chromatography (UHPLC) analysis.

In fact, Mini-UniPrep lets you prepare samples in one third the time required by other methods. Add up the time savings, plus the money saved from cutting multiple consumables out of the sample preparation process and you′ll see huge benefits for your laboratory.

The device can be used either manually or with a compressor unit. The multi-compressor can process up to 6 samples at one time, further improving sample processing time and reducing the risk of hand stress.

The Mini-UniPrep device is designed to fit into any autosampler accommodating 12 x 32 mm vials. Alternatively the septum can be pierced with a needle and the sample drawn off for manual injection into an analyzer.

Amber Mini-UniPrep Syringeless Filter
  • Protects samples from UV damage

Features and Benefits:
  • Amber colorant prevents photodegradation of light sensitive samples
  • Same colorant used in pharmaceutical containers designed to meet USP specifications for light resistance
  • Translucent amber chamber and plunger enable easy visual inspection

Applications:
  • Use with any compound that requires protection from light, such as catecholamines or vitamins

Slit Septa Mini-UniPrep Syringeless Filter
  • For high-throughput automation

Features and Benefits:
  • Slit septum cap enables Mini-UniPrep use with current robotics on HPLC instruments for high throughput automation
  • Durable yet flexible slit septum cap has been specially designed for instruments with sensitive sampling needs. Sample evaporation is minimal

Applications:
  • Use with standard robotics on HPLC instruments with sensitive needles, allowing for higher throughput

Features and Benefits:
  • All-in-one filtration process allows you to process sample loads in one-third the time
  • Wide range of membrane choices from 0.2 and 0.45 μm pore sizes to meet specific sample application requirements
  • Compatible with most major autosamplers
  • Fewer consumables required. Reduce costs by up to 40%

Anwendung

  • Schneller, einfacher Weg, um Partikel vor der HPLC zu entfernen
  • Ersetzen Sie Spritzenfilter und Autosampler-Gefäße durch eine Einweg-Einheit
  • Geben Sie die Probe in einem Drittel der Zeit auf

Das bereits zusammengebaute Filtrationsgerät dient dem Entfernen von Feststoffen aus der Probe. Jede Einheit hat eine Membran an der einen Seite des Kolbens und eine, an der anderen Seite befestigte Kappe/Septum. Das Filtrat wird durch positiven Druck durch die Membran gepresst, wenn Sie Kammer und Kolben ineinanderdrücken. Luft entweicht durch die Lüftungsöffnung und der Sperr-Ring dichtet luftdicht ab.

Rechtliche Hinweise

Mini-UniPrep is a registered trademark of Cytiva
Whatman is a registered trademark of Cytiva

Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.