GE28-9642-86
TempliPhi™ - 2000 Reaction Kit
Cytiva 28-9642-86
About This Item
Recommended Products
shelf life
Please be aware this product may be shipped 30 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
manufacturer/tradename
Cytiva 28-9642-86
storage condition
(S-re Denature buffer and control DNA at -70°C or -15°C - -30°C. S-re TempliPhi premix at -70°C. Do not s-re TempliPhi premix at -15°C - -30°C. Thaw the premix on ice and maintain at 0–4°C during handling. Do not allow premix - warm above 4°C prior - amplification)
shipped in
dry ice
storage temp.
−70°C
Related Categories
General description
Two different types of TempliPhi™ DNA Amplification Kits are available to meet different throughput requirements. illustra™ TempliPhi™ DNA Amplification Kit for 2000 reactions contains premixed components and generates templates after overnight incubation. The 100- and 500-reaction kits contain separate, unmixed components for enhanced stability.
The illustra™ TempliPhi™ DNA Sequencing Template Amplification Kit has a distinct protocol and workflow compared to the 100/500 reaction size. Procedures for each kit are not interchangeable. Prior optimization is needed.
Application
Features and Benefits
- Prepare circular DNA templates for cycle sequencing, cloning, and transformation in 4 to 6 h.
- Generate microgram quantities of template DNA from picogram amounts of starting material.
- Use amplified DNA directly for cycle sequencing without purification.
- Amplify DNA from bacterial or M13 liquid cultures, colonies, plaques, glycerol stocks, or purified circular (plasmid or M13) DNA.
- Simple protocol reduces time, labor, and consumables needed for template preparation, and workflow enables easy automation.
Analysis Note
Legal Information
On packaging and insert for kits:
For use only as licensed by Qiagen GmbH. and Cytiva. The Phi 29 DNA polymerase may not be re-sold or used except in conjunction with the other components of this kit. See US patent numbers 5,854,033, 6,124,120, 6,143,495, 6,323,009, 5,198,543, 5,576,204, and their equivalents in other countries.
On container:
Subject to proprietary rights of Cytiva. May not be re-sold or used except with the other components of this kit. See US patent numbers 5,576,204, and their equivalents in other countries.
related product
Storage Class Code
12 - Non Combustible Liquids
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service