Supelco

Hydrocarbon Index-Kit acc. to DIN EN ISO 9377-2/H53

Sinónimos:

DIN EN ISO 9377-2, Kit, H53-Kit

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41113319
NACRES:
NA.21

shelf life

limited shelf life, expiry date on the label

Quality Level

application(s)

environmental

Application

application test according EN ISO 9377- 2/H53 : in accordance

The kit allows users to extract and analyze 20 water samples (2 series of 10 water samples) in duplicate. Recovery and Blank analysis should be run in duplicate after each series.

The following solutions should be diluted as follows prior to use:
49574 - 1:10with n-heptane
51706 - 1:10with acetone (exact concentration should be a thousand times the desired application range)
The water sample is extracted with an extracting agent. Polar substances are removed by clean up on Florisil®. The purified aliquot is analyzed by capillary chromatography using a non-polar column and a flame ionization detector. The total peak area between n-decane and n-tetracontane is measured. The concentration of mineral oil is quantified against and external standard consisting of two specified mineral oils, and the hydrocarbon oil index is calculated.

Legal Information

Florisil is a registered trademark of U.S. Silica Company

Los componentes del kit también están disponibles por separado

Referencia del producto
Descripción
SDS

  • 52582-USupelclean Florisil®/Na2SO4 SPE Tube, glass hardware, PTFE frit, bed A 2 g (Florisil®), bed B 2 g (Na2SO4), volume 6 mL, pk of 48 pk 48SDS

  • 18602Mineral oil standard mixture Type A and B for EN ISO 9377-2, analytical standard, ~10 mg/mL in heptane (exact content on the reference material certificate) 10 mLSDS

  • 51706QC-Standard Solution for EN ISO 9377-2, analytical standard 1 mLSDS

  • 49574Extraction Medium Stock Solution, acc. to DIN EN ISO 9377-2 3 x 100 mLSDS

signalword

Danger

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Carc. 2 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Central nervous system

Storage Class

3 - Flammable liquids

flash_point_f

-0.4 °F

flash_point_c

-18 °C


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico