30501-M
Hidróxido de amonio solution
puriss. p.a., reag. ISO, reag. Ph. Eur., ≥25% NH3 basis
Sinónimos:
Agua amoniacal, Amoníaco acuoso
About This Item
Productos recomendados
agency
USP/NF
reag. ISO
reag. Ph. Eur.
Quality Level
grade
puriss. p.a.
form
liquid
expl. lim.
27 %
concentration
≥25% NH3
impurities
readily oxidisable substances, complies
≤0.00005% pyridine
≤0.0005% KMnO4 red. matter (as O)
≤1 ppm heavy metals (as Pb)
evapn. residue
≤0.0018%
density
0.892-0.910 g/mL at 20 °C
0.9 g/mL at 25 °C (lit.)
anion traces
carbonate (CO32-): ≤10 ppm
chloride (Cl-): ≤0.5 ppm
phosphate (PO43-): ≤0.5 ppm
silicate (as SiO2): ≤10 ppm
sulfate (SO42-): ≤2 ppm
sulfide (S2-): ≤0.2 ppm
cation traces
Ag: ≤0.02 ppm
Al: ≤0.5 ppm
Au: ≤0.1 ppm
Ba: ≤0.05 ppm
Bi: ≤0.1 ppm
Ca: ≤1 ppm
Cd: ≤0.05 ppm
Co: ≤0.05 ppm
Cr: ≤0.05 ppm
Cu: ≤0.1 ppm
Fe: ≤0.1 ppm
Ga: ≤0.02 ppm
In: ≤0.02 ppm
K: ≤0.5 ppm
Li: ≤0.02 ppm
Mg: ≤0.1 ppm
Mn: ≤0.05 ppm
Mo: ≤0.05 ppm
Na: ≤1 ppm
Ni: ≤0.05 ppm
Pb: ≤0.05 ppm
Pt: ≤0.1 ppm
Sn: ≤0.1 ppm
Sr: ≤0.2 ppm
Ti: ≤0.1 ppm
Tl: ≤0.05 ppm
Zn: ≤0.1 ppm
SMILES string
[NH4+].[OH-]
suitability
complies for appearance of solution
storage temp.
2-8°C
InChI
1S/H3N.H2O/h1H3;1H2
InChI key
VHUUQVKOLVNVRT-UHFFFAOYSA-N
¿Está buscando productos similares? Visita Guía de comparación de productos
Categorías relacionadas
Application
- Ammonium Hydroxide in Material Adsorption: Ammonium hydroxide is used to enhance the adsorption capacity of alginate-based magnetic nanocomposite beads for removing heavy metal ions from water, showcasing its effectiveness in water purification technologies (Russo et al., 2024).
- Capillary Electrophoresis for Nanoplastics: Ammonium hydroxide is utilized in developing methodologies for the separation and detection of nanoplastic particles using capillary electrophoresis, crucial for environmental monitoring and safety assessments (Adelantado et al., 2024).
Packaging
signalword
Danger
hcodes
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1 - Skin Corr. 1B - STOT SE 3
target_organs
Respiratory system
Storage Class
8A - Combustible corrosive hazardous materials
wgk_germany
WGK 2
flash_point_f
Not applicable
flash_point_c
Not applicable
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Artículos
This article validates the ability to perform cleanup of urine samples using HLB solid-phase extraction (SPE) for the analysis of opioids via tandem mass spectrometry (LC-MS/MS) after cleanup with the Supel™ Swift HLB 96-well plate.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico