跳轉至內容
Merck
全部照片(1)

重要文件

24010

Supelco

SP-2250

L × I.D. 30 m × 0.25 mm, df 0.20 μm

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41115710
eCl@ss:
32119290

材料

fused silica

agency

meets requirements for USP G3

參數

0-250 °C temperature (isothermal or programmed)

β值

313

df

0.20 μm

技術

gas chromatography (GC): suitable

長度 × 內徑

30 m × 0.25 mm

基質活性組

Non-bonded; poly(50% phenyl/50% methyl siloxane) phase

柱類型

capillary intermediate polar

尋找類似的產品? 前往 產品比較指南

一般說明

Application: The SP-2250 column is a non-bonded 50% phenyl polymer. It is highly effective for the analysis of polar compounds.
USP Code: This column meets USP G3 requirements.
Phase:
  • Non-bonded
  • Poly(50% phenyl/50% methyl siloxane)
Temp. Limits:
  • 0 °C to 250 °C (isothermal or programmed)

應用

Capillary column coated with SP®-2250 (methyl silicone-phenyl silicone, 1:1) stationary phase may be used in gas chromatographic analysis of azaarenes (benzacridines and dibenzacridines).

其他說明

We offer a variety of chromatography accessories including analytical syringes

法律資訊

SP is a registered trademark of Sigma-Aldrich Co. LLC

從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

D F Tomkins
Journal - Association of Official Analytical Chemists, 70(6), 1056-1058 (1987-11-01)
An isothermal gas chromatographic method for measuring alachlor in Micro-Tech (microencapsulated) formulations was tested by 5 collaborators. The samples were prepared in acetone, and alachlor was determined using a gas chromatographic column of 10% SP-2250 on 100-120 mesh Supelcoport. Di-n-pentylphthalate
D J Greenblatt et al.
Anesthesiology, 55(2), 176-179 (1981-08-01)
Plasma midazolam concentrations following single therapeutic doses can be quantitated using electron-capture gas-liquid chromatography. After addition of a benzodiazepine analogue as an internal standard, samples are extracted with benzeneisoamyl alcohol (98.5:1.5). The organic extract is evaporated to dryness, reconstituted, and
J E Wallace et al.
Clinical chemistry, 25(7), 1296-1300 (1979-07-01)
We describe the use of electron-capture gas chromatography or reversed-phase "high-performance" liquid chromatography for concurrent analysis for diazepam and nordiazepam in serum. In the gas-chromatographic analysis our use of a new chemically deactivated stationary liquid phase, SP 2250-DB (Supelco, Inc.)
V Gambaro et al.
Journal of analytical toxicology, 6(6), 321-323 (1982-11-01)
The gas chromatographic identification of barbiturates isolated from biological material is not optimal, and due to their polar nature, it is difficult to obtain good resolution on most columns. To improve resolution, flash alkylation appeared to be a reasonable alternative.
D Courtot
British journal of sports medicine, 10(3), 143-146 (1976-10-01)
At the request of the Service des Haras, our laboratory works on the toxicological problems of the sport-horse. These studies have resulted in the setting up of an anti-doping control for equestrian competitions of various types, not only flat racing.

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務