GE80-6484-51

2-D Clean-Up Kit

Cytiva 80-6484-51

同義詞:

2D Clean-Up Kit

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41105323
NACRES:
NA.25

特點

wetted part: no

製造商/商標名

Cytiva 80-6484-51

包裝

pkg of 50 samples

一般說明

2-D Clean-Up Kit is designed to prepare samples for 2-D electrophoresis that otherwise produce poor 2-D spot-maps due to high conductivity, high levels of interfering substances, or low protein concentration. The reagents quantitatively precipitate proteins while leaving interfering substances, such as detergents, salts, lipids, phenolics, and nucleic acids, in solution.

Treatment of the sample with 2-D Clean-Up Kit can improve the quality of 2-D electrophoresis results, reducing streaking, background staining, and other artifacts due to interfering contaminants. The kit can make 2-D analysis possible for samples that are otherwise too dirty or too dilute.

The 2-D Clean-Up Kit procedure uses precipitant and co-precipitant in combination to quantitatively precipitate proteins. Precipitated proteins are pelleted by centrifugation and the precipitate is further washed to remove nonprotein contaminants. After a second centrifugation, the resultant pellet is resuspended into denaturing sample solution for first-dimension IEF.

The procedure can be completed in 90 min and does not result in spot gain or loss. The kit contains sufficient reagents to process 50 samples of up to 100 μ each. The procedure can be scaled up for larger volumes or more dilute samples.

2-D Clean-Up Kit increases labeling efficiency and protein abundance when using 2-D Fluorescence Difference Gel Electrophoresis (2-D DIGE).

應用

Automated identification and quantitation of proteins and peptides using LC-MS/MS.

特點和優勢

  • Improves the quality of 2-D electrophoresis results by removing interfering contaminants
  • Quantitative precipitation separates proteins from detergents, salts, lipids, phenolics and nucleic acids
  • Delivers quantitative yield in about 90 min.

儲存和穩定性

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
The wash buffer should be placed at -20 °C at least 1 h before use and may be s-red in a -20 °C freezer

分析報告

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

象形圖

Environment

訊號詞

Danger

危險聲明

儲存類別代碼

8B - Non-combustible corrosive hazardous materials


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

條款

Mini Dialysis Kit from GE Healthcare Lifescience is designed for the dialysis of small sample volumes with minimal handling and sample loss and reduces the pronounced streaking on 2-D gels caused by low-molecular-weight contaminants.

Sample Grinding Kit from GE Healthcare is designed to disrupt cell or tissue samples for protein extraction.

2-D Clean-Up Kit from GE Healthcare is designed to prepare samples that would otherwise produce poor 2-D results.

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務