全部照片(3)
About This Item
經驗公式(希爾表示法):
C6H3Cl2NaO4S
CAS號碼:
分子量::
265.05
Beilstein:
3640643
EC號碼:
MDL號碼:
分類程式碼代碼:
12171500
PubChem物質ID:
NACRES:
NA.47
推薦產品
產品名稱
3,5-二氯-2-羟基苯磺酸钠, used for peroxide measurement
品質等級
化驗
≥98% (TLC)
形狀
powder
技術
titration: suitable
顏色
white to off-white
pH值
7 (20 °C, 53 g/L)
mp
>300 °C
溶解度
H2O: 50 mg/mL
應用
diagnostic assay manufacturing
hematology
histology
儲存溫度
room temp
SMILES 字串
[Na+].Oc1c(Cl)cc(Cl)cc1S([O-])(=O)=O
InChI
1S/C6H4Cl2O4S.Na/c7-3-1-4(8)6(9)5(2-3)13(10,11)12;/h1-2,9H,(H,10,11,12);/q;+1/p-1
InChI 密鑰
NMWCVZCSJHJYFW-UHFFFAOYSA-M
尋找類似的產品? 前往 產品比較指南
一般說明
3,5-二氯-2-羟基苯磺酸钠与4-氨基安替比林(4-AAP)和过氧化氢(H2O2)一起被用于血清和尿样中尿酸的显色定量。
應用
与4-氨基安替比林(4-AAP)和过氧化氢(H2O2)一起被用于偶联酶促反应中过氧化物酶的显色定量。 Trinder试剂的组分,与过氧化物酶一起用于测量自动化系统中过氧化氢的产生。
訊號詞
Warning
危險聲明
危險分類
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
標靶器官
Respiratory system
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
Eyeshields, Gloves, type N95 (US)
客戶也查看了
Use of 3,5-dichloro-2-hydroxybenzenesulfonic acid/4-aminophenazone chromogenic system in direct enzymatic assay of uric acid in serum and urine.
Fossati P, et al.
Clinical Chemistry, 26(2), 227-231 (1980)
Lucas F de Castro et al.
Analytical and bioanalytical chemistry, 411(19), 4919-4928 (2019-04-04)
Microfluidic paper-based devices (μPADs) and wearable devices have been highly studied to be used as diagnostic tools due to their advantages such as simplicity and ability to provide instrument-free fast results. Diseases such as periodontitis and diabetes mellitus can potentially
Teresa Ramon-Marquez et al.
Talanta, 187, 83-90 (2018-06-02)
In this study, we have optimised the sterically directed attachment of biomolecules on the surface of coaxial membranes prepared by co-electrospinning which have been proved to be a material with very high performance for the development of biosensors with optical
J D Artiss et al.
Clinical biochemistry, 16(6), 334-337 (1983-12-01)
A study into the substitution of sodium 2-hydroxy-3,5-dichlorobenzenesulfonate for phenol in the indicator reaction for an automated glucose procedure is presented. Apart from having physical properties that are more conducive to easy handling than phenol, the former material affords considerably
Ana C Fernandes et al.
New biotechnology, 47, 39-49 (2018-04-24)
The need for fast and comprehensive characterization of biocatalysts has pushed the development of new screening platforms based on microfluidics, capable of monitoring several parameters simultaneously, with new configurations of liquid handling, sample treatment and sensing. Modular microfluidics allows the
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務